A fully automated objective striatal analysis (OSA) program that quantitates dopamine transporter uptake in subjects with suspected Parkinson's disease was applied to images from clinical 123I-ioflupane studies. The striatal binding ratios or alternatively the specific binding ratio (SBR) of the lowest putamen uptake was computed, and receiver-operating-characteristic (ROC) analysis was applied to 94 subjects to determine the best discriminator using this quantitative method. Methods: Ninety-four 123I-ioflupane SPECT scans were analyzed from patients referred to our clinical imaging department and were reconstructed using the manufacturer-supplied reconstruction and filtering parameters for the radiotracer. Three trained readers conducted independent visual interpretations and reported each case as either normal or showing dopaminergic deficit (abnormal). The same images were analyzed using the OSA software, which locates the striatal and occipital structures and places regions of interest on the caudate and putamen. Additionally, the OSA places a region of interest on the occipital region that is used to calculate the background-subtracted SBR. The lower SBR of the 2 putamen regions was taken as the quantitative report. The 33 normal (bilateral comma-shaped striata) and 61 abnormal (unilateral or bilateral dopaminergic deficit) studies were analyzed to generate ROC curves. Results: Twenty-nine of the scans were interpreted as normal and 59 as abnormal by all 3 readers. For 12 scans, the 3 readers did not unanimously agree in their interpretations (discordant). The ROC analysis, which used the visual-majority-consensus interpretation from the readers as the gold standard, yielded an area under the curve of 0.958 when using 1.08 as the threshold SBR for the lowest putamen. The sensitivity and specificity of the automated quantitative analysis were 95% and 89%, respectively. Conclusion: The OSA program delivers SBR quantitative values that have a high sensitivity and specificity, compared with visual interpretations by trained nuclear medicine readers. Such a program could be a helpful aid for readers not yet experienced with 123I-ioflupane SPECT images and if further adapted and validated may be useful to assess disease progression during pharmaceutical testing of therapies. ? 2013 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
机译:在临床123I-ioflupane研究的图像中应用了一种全自动的客观纹状体分析(OSA)程序,该程序可对怀疑患有帕金森氏病的受试者的多巴胺转运蛋白摄取进行定量。计算最低的壳聚糖吸收的纹状体结合率或特异性结合率(SBR),并使用这种定量方法对94名受试者进行受试者工作特征(ROC)分析,以确定最佳区分剂。方法:对转诊至我们的临床影像部门的患者进行了94例123I-ioflupane SPECT扫描,并使用制造商提供的放射性示踪剂重建和过滤参数对其进行了重建。三名训练有素的读者进行了独立的视觉解释,并将每例病例报告为正常或表现出多巴胺能缺乏(异常)。使用OSA软件分析了相同的图像,该软件可以定位纹状体和枕骨结构,并将感兴趣的区域放在尾状和壳状核上。此外,OSA在枕骨区域上放置了一个感兴趣的区域,该区域用于计算减去背景的SBR。将2个壳状核果区域中较低的SBR用作定量报告。分析了33例正常(双侧逗号形条纹)和61例异常(单侧或双侧多巴胺能缺陷)研究,以生成ROC曲线。结果:所有3位阅读器将29项扫描解释为正常,将59项解释为异常。对于12个扫描,这3个读者的解释不一致(不一致)。 ROC分析使用读者的视觉多数共识解释作为金标准,当使用1.08作为最低酪蛋白的阈值SBR时,曲线下面积为0.958。自动定量分析的灵敏度和特异性分别为95%和89%。结论:与受过训练的核医学读者的视觉解释相比,OSA程序可提供具有高灵敏度和特异性的SBR定量值。这样的程序可能对尚未使用123I-ioflupane SPECT图像的读者提供有用的帮助,并且如果进一步修改和验证,则可能对评估药物治疗期间的疾病进展有用。 ? 2013年,核医学与分子影像学会,公司。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号