Our objective was to determine the stability of stabilized (99m)Tc-hexamethylpropylene amine oxime ((99m)Tc-d,l-HMPAO) dispensed by vial and syringe, with the storage time and labeling activity varied. METHODS: (99m)Tc-d,l-HMPAO was labeled according to the manufacturer's instructions, but with modification of the (99m)TcO(4)Na activity. Two groups were prepared: 1,110 MBq (30 mCi) and 2,600-3,700 MBq (70.3-100 mCi). Five minutes after labeling, the radiochemical purity (RCP) of the vial content was determined. Afterward, the same activity was distributed into two 2-mL syringes and into the manufacturer's vial. In one of the syringes, the radiopharmaceutical stayed in contact with the needle for 4 h. At 2 and 4 h after labeling, the RCP of the vial and syringe content was checked and compared. RESULTS: The mean RCP of stabilized (99m)Tc-d,l-HMPAO labeled with 1,110 MBq (30 mCi) and stored in a vial decreased from 93.1% at 5 min to 92.1% at 2 h and to 91.1% at 4 h. With storage in a syringe, the RCP decreased from 89.8% at 2 h to 88.7% at 4 h. This diminution increased for labeling with higher activities (2,600-3,700 MBq [70.3-100 mCi]), ranging from 91.4% at 5 min, 89.0% at 2 h, and 85.3% at 4 h in a vial and from 85.9% at 2 h to 80.2% in a syringe. (99m)TcO(2) and secondary (99m)Tc-HMPAO were the main impurities at t = 0. (99m)TcO(4)(-) was an impurity that increased with time in both vials and syringes but significantly so in syringes. All these impurities were higher with labeling activities in the range of 2,600-3,700 MBq (70.3-100 mCi). Contact of the needle with (99m)Tc-d,l-HMPAO sharply decreased the RCP to 57.1% at 4 h. CONCLUSION: The RCP of stabilized (99m)Tc-d,l-HMPAO decreases significantly in both vials and syringes with high labeling activities. The product is less stable when stored in a syringe than in a vial. The fraction of dose in contact with the needle affects the RCP results.
机译:我们的目标是确定通过小瓶和注射器分配的稳定的(99m)Tc-六甲基丙烯胺肟((99m)Tc-d,1-HMPAO)的稳定性,随存储时间和标记活性的变化而变化。方法:根据制造商的说明标记(99m)Tc-d,1-HMPAO,但修改(99m)TcO(4)Na活性。准备了两组:1,110 MBq(30 mCi)和2,600-3,700 MBq(70.3-100 mCi)。标记五分钟后,确定小瓶内容物的放射化学纯度(RCP)。然后,将相同的活性分配到两个2-mL注射器和制造商的小瓶中。在其中一个注射器中,放射性药物与针头保持接触4小时。贴标后2和4小时,检查并比较样品瓶的RCP和注射器内含物。结果:标记为1,110 MBq(30 mCi)并保存在小瓶中的稳定化(99m)Tc-d,1-HMPAO的平均RCP从5分钟时的93.1%降至2小时时的92.1%和4小时时的91.1% 。将其保存在注射器中后,RCP从2小时的89.8%降至4小时的88.7%。对于具有较高活性的标签(2,600-3,700 MBq [70.3-100 mCi]),此减小量有所增加,范围从5分钟的91.4%,2小时的89.0%和4小时的45.3%在小瓶中从85.9% h在注射器中达到80.2%。 (99m)TcO(2)和次要(99m)Tc-HMPAO是t = 0时的主要杂质。(99m)TcO(4)(-)是随时间推移在小瓶和注射器中增加的杂质,但在注射器。所有这些杂质的标记活性在2,600-3,700 MBq(70.3-100 mCi)范围内都较高。针头与(99m)Tc-d,1-HMPAO的接触在4 h时使RCP急剧降低至57.1%。结论:在具有高标记活性的小瓶和注射器中,稳定的(99m)Tc-d,1-HMPAO的RCP均显着降低。当储存在注射器中时,产品的稳定性要比小瓶中的不稳定。与针头接触的剂量比例会影响RCP结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号