Stainless steel 316 is a candidate structural material for heavy liquid metal spallation neutron sources and fast reactor systems. Impedance spectroscopy (IS) provides a means of real-time measurements of the stability of protective oxide scales in these systems. The IS technique has been shown to yield quantitative results at lower temperatures, but does not yet yield quantitative results at temperatures of interest for engineering applications. To understand this, pre-oxidized stainless steel 316 samples were immersed in oxygen-saturated stagnant lead bismuth eutectic at 550 degrees C for 1335 h. During the exposure, real-time impedance spectroscopy was taken from different samples. Negligible impedance was observed from one sample at the end of 1335 h, indicating that the oxide scale was non-protective. A variety of microanalysis techniques revealed that oxide layers formed on the sample surface suffered corrosion attack from the LBE. A duplex oxide structure composed of outer iron oxide and inner iron chromium oxide was found on some sample surface area. The major phases of the duplex oxide scales were Fe3O4 and FeCr2O4. The high conductivity of this duplex scale explains the corrosion rate as well as the lack of IS response.
机译:不锈钢316是重金属液态散裂中子源和快速反应堆系统的候选结构材料。阻抗谱(IS)提供了一种实时测量这些系统中保护性氧化皮的稳定性的方法。已经证明,IS技术可在较低温度下产生定量结果,但在工程应用所需的温度下尚未产生定量结果。为了理解这一点,将预氧化的316不锈钢样品在550℃下浸入氧饱和的停滞的铋铋共晶中1335 h。在曝光期间,从不同样品中获取了实时阻抗谱。在1335小时结束时从一个样品中观察到的阻抗可忽略不计,这表明氧化物垢是非保护性的。各种微分析技术表明,样品表面上形成的氧化层受到LBE的腐蚀侵蚀。在某些样品表面积上发现了由外铁氧化物和内铁铬氧化物组成的双相氧化物结构。双相氧化皮的主要相为Fe3O4和FeCr2O4。这种双刻度尺的高电导率说明了腐蚀速率以及IS反应的缺乏。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号