首页> 外文期刊>Journal of Pharmaceutical and Biomedical Analysis: An International Journal on All Drug-Related Topics in Pharmaceutical, Biomedical and Clinical Analysis >Determination of cocaine and benzoylecgonine by direct injection of human urine into a column-switching liquid chromatography system with diode-array detection.
【24h】

Determination of cocaine and benzoylecgonine by direct injection of human urine into a column-switching liquid chromatography system with diode-array detection.

机译:通过将人类尿液直接注入具有二极管阵列检测功能的柱切换液相色谱系统中来测定可卡因和苯甲酰芽子碱。

获取原文
获取原文并翻译 | 示例
       

摘要

A method for the determination of cocaine (COC) and benzoylecgonine (BZE) in human urine using a column-switching liquid chromatography system is reported. A homemade precolumn (20 mm x 4.6 mm i.d.) dry-packed with Alltech ODS-C18 (35-750 microm) was employed as an extraction precolumn in order to extract and concentrate the COC and BZE from the human urine sample. The analytes were continuously transferred to the analytical column (Spherisorb-C8, 250 mm x 4.6 mm i.d.; dp = 5 microm) by means of the switching arrangement in the backflush mode. Detection was carried out at 235 nm in a UV-diode array detector. The validation of the method revealed analytes quantitative recoveries (96-102%) at three concentrations in the range from 0.25 to 4.00 and from 0.5 to 12.0 microg/mL for COC and BZE, respectively. These values demonstrate the excellent extraction efficiency of the precolumn. The detection limits for COC and BZE at a signal-to-noise ratio of 3 were 0.08 and 0.15 microg/mL when a sample volume of 50microL was injected. The overlap of sample preparation, analysis and recondition of the precolumn increases the sample throughput to four samples per hour. The proposed method has been applied to the determination of COC and BZE in human urine samples from 73 suspecting drug addicts. Urine concentrations of 1.0-118.10 microg of BZE/mL and 0.1-41.0 microg of COC/mL were found.
机译:报道了一种使用柱切换液相色谱系统测定人尿中可卡因(COC)和苯甲酰芽子碱(BZE)的方法。干包装了Alltech ODS-C18(35-750微米)的自制预柱(20 mm x 4.6 mm i.d.)被用作萃取前柱,以便从人尿液样品中萃取和浓缩COC和BZE。通过反吹模式下的切换装置将分析物连续转移至分析柱(Spherisorb-C8,内径250 mm x 4.6 mm; dp = 5微米)。在UV二极管阵列检测器中于235nm进行检测。该方法的有效性表明,COC和BZE的三种浓度分别为0.25至4.00和0.5至12.0 microg / mL时,分析物的定量回收率(96-102%)。这些值证明了预柱的出色提取效率。当进样量为50 microL时,信噪比为3时,COC和BZE的检出限为0.08和0.15 microg / mL。样品制备,分析和预柱再处理的重叠将样品通量提高到每小时四个样品。所提出的方法已用于测定73名可疑吸毒者的人尿液样品中的COC和BZE。发现尿液浓度为1.0-118.10微克BZE / mL和0.1-41.0微克COC / mL。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号