首页> 外文期刊>Journal of oral rehabilitation >Detection of sleep bruxism: Comparison between an electromyographic and electrocardiographic portable holter and polysomnography
【24h】

Detection of sleep bruxism: Comparison between an electromyographic and electrocardiographic portable holter and polysomnography

机译:睡眠磨牙症的检测:肌电图和心电图便携式动态心电图和多导睡眠图的比较

获取原文
获取原文并翻译 | 示例
           

摘要

Summary: Recent polysomnographic (PSG) studies showed that the sleep bruxism (SB) event is preceded by a sudden shift in autonomic cardiac activity. Therefore, heart rate could be the simplest-to-record parameter for use in addition to portable home EMG monitoring to improve the accuracy in automatic detection of SB events. The aim of the study was to compare the detection of SB episodes by combined surface electromyography and heart rate (HR) recorded by a compact portable device (Bruxoff?), with the scoring of SB episodes by a PSG recording. Twenty-five subjects (14 'probable' bruxers and 11 non-bruxers) were selected for the study. Each subject underwent the Bruxoff and the PSG recordings during the same night. Rhythmic masseter muscle activities (RMMAs) were scored according to published criteria. Correlation coefficients and the Bland-Altman plots were calculated to measure the correlation and agreement between the two methods. Results showed a high correlation (Pearson's r = 0·95, P 0·0001) and a high agreement (bias = 0·05) between Bruxoff and the PSG. Furthermore, the receiver operating characteristic curve analysis showed a high sensitivity and specificity of the portable device (92·3% and 91·6%, respectively) when the cut-off was set at 4 SB episodes per hour according to published criteria. The Bruxoff device showed a good diagnostic accuracy to differentiate RMMA from other oromotor activities. These findings are important in the light of the need for simple and reliable portable devices for the diagnosis of SB both in the clinical and research settings.
机译:摘要:最近的多导睡眠图(PSG)研究表明,睡眠磨牙症(SB)事件之前是自主心脏活动的突然转变。因此,除了便携式家庭EMG监测以外,心率可能是最容易记录的参数,以提高SB事件自动检测的准确性。这项研究的目的是比较由紧凑型便携式设备(Bruxoff?)记录的表面肌电图和心率(HR)组合对SB发作的检测与PSG记录对SB发作的评分。本研究选择了25名受试者(14名“可能”的男性和11名非男性)。每个对象在同一晚都接受了Bruxoff和PSG录音。根据公开的标准对节律性咬肌活动(RMMA)进行评分。计算相关系数和Bland-Altman图以测量两种方法之间的相关性和一致性。结果显示Bruxoff与PSG之间的相关性很高(Pearson r = 0·95,P <0·0001),并且一致性很高(bias = 0·05)。此外,接收机的工作特性曲线分析显示,根据发布的标准将截止频率设置为每小时4 SB时,便携式设备具有很高的灵敏度和特异性(分别为92·3%和91·6%)。 Bruxoff装置显示出良好的诊断准确性,可将RMMA与其他口腔运动活动区分开。考虑到在临床和研究环境中需要简单可靠的便携式设备来诊断SB,这些发现很重要。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号