...
首页> 外文期刊>Journal of oral rehabilitation >Influence of the thickness of silicone registration material as a means for occlusal contact examination - an explorative study with different tooth clenching intensities
【24h】

Influence of the thickness of silicone registration material as a means for occlusal contact examination - an explorative study with different tooth clenching intensities

机译:有机硅配准材料厚度对咬合接触检查的影响-不同牙齿紧握强度的探索性研究

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Summary: This study explored the influence of the thickness of silicone registration material on evaluation of the occlusal contact area and number of occlusal contact points, during increasing tooth clenching conditions in normal subjects. Twenty-four subjects with no more than one missing tooth per quadrant participated. Surface electro-myography was recorded from the masseter muscle. As a baseline measurement, intercuspal position was maintained with minimal force, and occlusal contact was recorded using blue silicone material. Occlusal contact was also recorded at 20% maximum voluntary contraction (MVC) and 40% MVC using visual feedback. The occlusal contact area and number of occlusal contact points were analysed using five levels of thickness of silicone registration material: Level 1 (0-149 μm); Level 2 (0-89 μm); Level 3 (0-49 μm); Level 4 (0-29 μm); and Level 5 (0-4 μm). The anterior part and the left and right posterior regions of the dental arch were analysed separately. At all detection levels, the occlusal contact area significantly increased from baseline to 20% MVC and to 40% MVC in the molar area (P < 0·05). In the anterior part, the occlusal contact area significantly increased from baseline to 20% MVC and to 40% MVC only when using Level 5. The number of occlusal contact points significantly increased from baseline to 20% MVC and to 40% MVC only when using Level 5 in the molar area (P < 0·05). It suggested that occlusal contacts may be different at low tooth clenching intensity with potential effects on the teeth or periodontal tissues.
机译:摘要:本研究探讨了正常受试者在增加牙齿紧握状况期间,有机硅配准材料厚度对咬合接触面积和咬合接触点数量的影响。 24个受试者的每象限不超过一颗缺牙。从咬肌记录表面肌电图。作为基线测量,以最小的力保持腕间位置,并使用蓝色有机硅材料记录咬合接触。还使用视觉反馈记录了职业接触的最大自愿收缩率(MVC)为20%和MVC为40%。使用有机硅配准材料的五个厚度级别来分析咬合接触面积和咬合点数量:级别1(0-149μm);级别2(0-89μm);级别3(0-49μm);级别4(0-29μm);和5级(0-4μm)。分别对牙弓的前部和左右后部区域进行分析。在所有检测水平下,磨牙区域的咬合接触面积均从基线显着增加到20%MVC和40%MVC(P <0·05)。在前部,仅当使用第5级时,咬合接触面积才从基线显着增加到20%MVC和40%MVC。仅当使用第5级时,咬合接触点的数量才从基线显着增加到20%MVC和40%MVC。磨牙区域的水平为5(P <0·05)。这表明在低牙齿紧握强度下,咬合接触可能会有所不同,可能会对牙齿或牙周组织产生影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号