首页> 外文期刊>Journal of occupational and environmental hygiene >Effects of liquid cooling garments on recovery and performance time in individuals performing strenuous work wearing a firefighter ensemble.
【24h】

Effects of liquid cooling garments on recovery and performance time in individuals performing strenuous work wearing a firefighter ensemble.

机译:液体冷却服对穿着消防员服装进行艰苦工作的人的恢复时间和表演时间的影响。

获取原文
获取原文并翻译 | 示例
       

摘要

This study investigated the effects of body cooling using liquid cooling garments (LCG) on performance time (PT) and recovery in individuals wearing a fully equipped prototype firefighter ensemble (PFE) incorporating a self-contained breathing apparatus (SCBA). Six healthy male participants (three firefighters and three non-firefighters) completed six experimental sessions in an environmental chamber (35 degrees C, 50% relative humidity), consisting of three stages of 15 min exercise at 75% VO2max, and 10 min rest following each exercise stage. During each session, one of the following six conditions was administered in a randomized order: control (no cooling, CON); air ventilation of exhaust SCBA gases rerouted into the PFE (AV); top cooling garment (TCG); TCG combined with AV (TCG+AV); a shortened whole body cooling garment (SCG), and SCG combined with AV (SCG+AV). Results showed that total PT completed was longer under SCG and SCG+AV compared with CON, AV, TCG, and TCG+AV (p<0.01). Magnitude of core temperature (Tc) elevation was significantly decreased when SCG was utilized (p<0.01), and heart rate recovery rate (10 min) was enhanced under SCG, SCG+AV, TCG, and TCG+AV compared with CON (p<0.05). Estimated Esw rate (kg.h(-1)) was the greatest in CON, 1.62 (0.37), and the least in SCG+AV 0.98 (0.44): (descending order: CON>AV>TCG=TCG+AV>SCG>SCG+AV) without a statistical difference between the conditions (p<0.05). Results of the present study suggest that the application of LCG underneath the PFE significantly improves the recovery during a short period of rest and prolongs performance time in subsequent bouts of exercise. LCG also appears to be an effective method for body cooling that promotes heat dissipation during uncompensable heat stress.
机译:这项研究调查了身穿配备了独立呼吸器(SCBA)的装备齐全的原型消防员合奏(PFE)的个人,使用液体冷却服(LCG)进行身体冷却对运动时间(PT)和恢复的影响。六名健康的男性参与者(三名消防员和三名非消防员)在一个环境室内(35摄氏度,相对湿度50%)完成了六个实验课,包括三个阶段,以75%VO2max进行15分钟的运动,然后休息10分钟每个运动阶段。在每个阶段中,以随机顺序管理以下六个条件之一:对照(无冷却,CON);重新排入PFE(AV)的SCBA排气的空气通风;顶部冷却服(TCG); TCG结合AV(TCG + AV);缩短了的全身降温衣(SCG),以及SCG与AV(SCG + AV)的组合。结果表明,与CON,AV,TCG和TCG + AV相比,SCG和SCG + AV下完成的PT更长(p <0.01)。与CON相比,使用SCG时,核心温度(Tc)升高幅度显着降低(p <0.01),并且在SCG,SCG + AV,TCG和TCG + AV下,心率恢复率(10 min)提高。 <0.05)。估计的Esw率(kg.h(-1))在CON中最大,1.62(0.37),在SCG + AV 0.98(0.44)中最小:(降序:CON> AV> TCG = TCG + AV> SCG > SCG + AV),条件之间无统计学差异(p <0.05)。本研究的结果表明,在PFE下方使用LCG可以显着改善短时间休息期间的恢复,并延长后续运动时的运动时间。 LCG似乎也是一种有效的降温方法,可在无法补偿的热应力下促进散热。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号