首页> 外文期刊>Clinical Radiology: Journal of the Royal College of Radiologists >Re: Comprehensive MRA of the lower limbs including high-resolution extended-phase infra-inguinal imaging with gadobenate dimeglumine: Initial experience with inter-individual comparison to the blood-pool contrast agent gadofosveset trisodium
【24h】

Re: Comprehensive MRA of the lower limbs including high-resolution extended-phase infra-inguinal imaging with gadobenate dimeglumine: Initial experience with inter-individual comparison to the blood-pool contrast agent gadofosveset trisodium

机译:回复:下肢的全面MRA,包括加多贝酸二甲双胍的高分辨率延长相红外成像:与血池造影剂加多福韦塞三钠进行个体间比较的初步经验

获取原文
获取原文并翻译 | 示例

摘要

I was interested to read the above article comparing "newer" standard (gadobenate) versus blood-pool contrast agents (BPCA; gadofosveset) for lower-limb magnetic resonance angiography (MRA) in a somewhat small series of 20 patients.1 If MRA is indeed the authors' standard peripheral arterial imaging method, and more numbers could have been provided, then the samples are surely somewhat inadequate, given that even a basic tool such as Altman's nomogram (before going on to more complex calculations) would suggest sample sizes of 200 for starters, in order to obtain a meaningful analysis.
机译:我很感兴趣阅读以上文章,比较了20例患者中较小系列的下肢磁共振血管造影(MRA)的“较新”标准品(加多贝酸钠)与血池造影剂(BPCA;加多福韦塞)的比较。1确实是作者的标准外周动脉成像方法,并且可以提供更多的数字,所以样本肯定有些不足,因为即使使用基本工具(如Altman诺模图)(在进行更复杂的计算之前)也会建议样本大小200对于初学者来说,是为了获得有意义的分析结果。