OBJECT: Clinical application of the convection-enhanced delivery (CED) technique is currently limited by low infusion speed and reflux of the delivered agent. The authors developed and evaluated a new step-design cannula to overcome present limitations and to introduce a rapid, reflux-free CED method for future clinical trials. METHODS: The CED of 0.4% trypan blue dye was performed in agarose gel to test cannula needles for distribution and reflux. Infusion rates ranging from 0.5 to 50 microl/minute were used. Agarose gel findings were translated into a study in rats and then in cynomolgus monkeys (Macacafascicularis) by using trypan blue and liposomes to confirm the efficacy of the reflux-free step-design cannula in vivo. Results of agarose gel studies showed reflux-free infusion with high flow rates using the step-design cannula. Data from the study in rats confirmed the agarose gel findings and also revealed increasing tissue damage at a flow rate above 5-microl/minute. Robust reflux-free delivery and distribution of liposomes was achieved using the step-design cannula in brains in both rats and nonhuman primates. CONCLUSIONS: The authors developed a new step-design cannula for CED that effectively prevents reflux in vivo and maximizes the distribution of agents delivered in the brain. Data in the present study show reflux-free infusion with a constant volume of distribution in the rat brain over a broad range of flow rates. Reflux-free delivery of liposomes into nonhuman primate brain was also established using the cannula. This step-design cannula may allow reflux-free distribution and shorten the duration of infusion in future clinical applications of CED in humans.
机译:目的:对流增强输送(CED)技术的临床应用目前受到输液速度低和输送剂回流的限制。作者开发并评估了一种新的分步设计套管,以克服目前的局限性,并为将来的临床试验引入一种快速,无反流的CED方法。方法:在琼脂糖凝胶中进行0.4%锥虫蓝染料的CED试验,以测试套管针的分布和回流情况。使用的输注速度为0.5至50微升/分钟。通过使用锥虫蓝和脂质体将琼脂糖凝胶的发现转化为在大鼠中的研究,然后在食蟹猴(Macacafascicularis)中进行了研究,以确认无回流分步设计套管在体内的功效。琼脂糖凝胶研究的结果表明,采用分步设计的插管可实现高流速的无回流输注。来自大鼠的研究数据证实了琼脂糖凝胶的发现,并且还揭示了以高于5微升/分钟的流速增加的组织损伤。使用分步设计的套管在大鼠和非人类灵长类动物的大脑中实现了无逆流的脂质体的强大传递和分布。结论:作者开发了一种新的CED阶梯式设计插管,该插管可有效防止体内反流,并最大程度地增加脑中传递的药物分布。本研究中的数据显示,在广泛的流速范围内,无回流输注在大鼠脑中的分布体积恒定。还使用套管建立了脂质体到非人类灵长类动物脑中的无回流递送。这种分步设计的插管可实现无反流分配并缩短CED在人类未来临床应用中的输注时间。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号