Are marginal bone levels and implant stability/mobility affected by single-stage platform switched dental implants? A comparative clinical study

机译:单阶段平台转换式牙种植体会影响边缘骨水平和种植体稳定性/活动性吗?比较临床研究

获取原文
获取原文并翻译 | 示例
           

摘要

Objectives: The aim of this study was to evaluate short-term bone level and stability/mobility measurement alterations at platform switched (PS) and standard platform (SP) implants placed in mandibular premolar/molar regions using a single-stage protocol. Materials and methods: Sixteen PS and 16 SP implants restorated with fixed prosthesis were included. Standard implant dimensions were used for both implant systems. After 3 months of osseointegration, implants were connected to abutments and final restorations were performed. Marginal bone loss was measured by standardized periapical radiographs. Implant stability/mobility was determined by resonance frequency analysis (RFA) and mobility measuring (MM) device values. Peri-implant parameters were evaluated with clinical periodontal indices and all parameters were assessed at baseline, 1, 3, and 6 months after the surgery. Results: After 6 months, all implants showed uneventful healing. Radiographic evaluation showed a mean bone loss of 0.72 mm for PS and 0.56 mm for SP implants, and there were no significant differences between implant types. At 6 months, mean implant stability quotient (ISQ) values were 73.38 and 77 for PS and SP implants, respectively. Mean MM values were -4.75 for PS and -6.38 for SP implants. Mean MM values were lower for SP implants compared to PS implants at all time points. No significant differences were detected between implant types according to clinical peri-implant parameters. Conclusions: The micro-gap at crestal level which immediately exposed to the oral cavity in non-submerged two part implants seems to have adverse influence on the marginal bone level.
机译:目的:本研究的目的是使用单阶段方案评估放置在下颌前磨牙/磨牙区域的平台交换(PS)和标准平台(SP)植入物的短期骨水平和稳定性/运动性测量改变。材料和方法:包括16个用固定修复体修复的PS和16 SP植入物。两个植入物系统均使用标准植入物尺寸。骨整合3个月后,将种植体连接至基台,并进行最终修复。边缘骨丢失通过标准的根尖X线片测量。通过共振频率分析(RFA)和迁移率测量(MM)装置值确定植入物的稳定性/迁移率。用临床牙周指数评估植入物周围参数,并在手术后1、3和6个月时评估所有参数。结果:6个月后,所有植入物均恢复正常。影像学评估显示PS植入物的平均骨丢失为0.72 mm,SP植入物的平均骨丢失为0.56 mm,并且植入物类型之间无显着差异。在6个月时,PS和SP植入物的平均植入物稳定性商(ISQ)值分别为73.38和77。 PS植入物的平均MM值为-4.75,SP植入物的平均MM值为-6.38。在所有时间点,SP植入物的平均MM值均低于PS植入物。根据临床植入物周围参数,在植入物类型之间未检测到显着差异。结论:在非浸入式两部分植入物中,立即暴露于口腔的缝隙水平的微间隙似乎对边缘骨水平有不利影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号