首页> 外文期刊>Clinical oral implants research >Influence of implant microstructure on the osseointegration of immediate implants placed in periodontally infected sites. A histomorphometric study in dogs.
【24h】

Influence of implant microstructure on the osseointegration of immediate implants placed in periodontally infected sites. A histomorphometric study in dogs.

机译:种植体的微观结构对放置在牙周感染部位的即刻种植体的骨整合的影响。狗的组织形态计量学研究。

获取原文
获取原文并翻译 | 示例
           

摘要

The aim of this study was to evaluate the influence of implant microstructure on the osseointegration of immediate implants placed into infected sites. During 12 weeks, periodontitis was induced in six dogs in the areas of the first to fourth mandibular premolars of both sides. The teeth were extracted and the implants were placed immediately. Implant placement was randomly assigned so that for each side in the mandible a different implant surface, a new grit-blasted/acid-etched group 1 or titanium plasma spray surface group 2 was used, totaling 36 implants in the experiment. The animals were killed 12 weeks after implant placement. Two histomorphometric analyses were performed: percentage of bone/implant contact (BIC) and analyses of the bone density in adjacent and distant areas from the implant surface. The results showed that the percentages of BIC were 52.7% and 42.7% for groups 1 and 2, respectively. The bone density analysis revealed that the percentages of bone in the adjacent areas were 66.6% and 58.8%, and in the distant areas from the implants were 58.7% and 55.8% for groups 1 and 2, respectively. The mean differences of BIC were verified through the Mann-Whitney test and differences in bone density through the Kruskal-Wallis test. The differences were not statistically significant (P>0.05). In conclusion, osseointegration of implants placed into a more challenging healing situation such as immediate implants into periodontally compromised sites was successful for both surfaces; however, the grit-blasted/acid-etched surface, although not statistically significant, had a slightly better performance when compared to the titanium plasma spray surface for all the parameters studied.
机译:这项研究的目的是评估植入物微观结构对放置在感染部位的即刻植入物骨整合的影响。在12周内,在两侧第一至第四下颌前磨牙区域的六只狗中诱发了牙周炎。拔出牙齿并立即放置植入物。随机分配植入物位置,以便在下颌骨的每一侧使用不同的植入物表面,使用新的喷砂/酸蚀组1或钛等离子喷涂表面组2,在实验中总计36个植入物。植入植入物后12周将动物处死。进行了两个组织形态计量学分析:骨/植入物接触(BIC)的百分比,以及与植入物表面相邻和相距较远区域的骨密度分析。结果表明,第一组和第二组的BIC百分比分别为52.7%和42.7%。骨密度分析显示,第1组和第2组在邻近区域的骨百分比分别为66.6%和58.8%,在远离植入物的区域分别为58.7%和55.8%。通过Mann-Whitney检验验证了BIC的平均差异,通过Kruskal-Wallis检验验证了骨密度的差异。差异无统计学意义(P> 0.05)。总之,植入物的骨整合处于更具挑战性的愈合情况下,例如将两个表面立即植入牙周受损部位均成功。然而,喷砂/酸蚀表面尽管在统计上并不显着,但在所有研究参数方面,与钛等离子喷涂表面相比,其性能稍好。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号