OBJECTIVES: Internal tapered connections were developed to improve biomechanical properties and to reduce mechanical problems found in other implant connection systems. The purpose of this study was to evaluate the effects of mechanical loading and repeated insertion/removal cycles on the torque loss of abutments with internal tapered connections. MATERIAL AND METHODS: Sixty-eight conical implants and 68 abutments of two types were used. They were divided into four groups: groups 1 and 3 received solid abutments, and groups 2 and 4 received two-piece abutments. In groups 1 and 2, abutments were simply installed and uninstalled; torque-in and torque-out values were measured. In groups 3 and 4, abutments were installed, mechanically loaded and uninstalled; torque-in and torque-out values were measured. Under mechanical loading, two-piece abutments were frictionally locked into the implant; thus, data of group 4 were catalogued under two subgroups (4a: torque-out value necessary to loosen the fixation screw; 4b: torque-out value necessary to remove the abutment from the implant). Ten insertion/removal cycles were performed for every implant/abutment assembly. Data were analyzed with a mixed linear model (P< or =0.05). RESULTS: Torque loss was higher in groups 4a and 2 (over 30% loss), followed by group 1 (10.5% loss), group 3 (5.4% loss) and group 4b (39% torque gain). All the results were significantly different. As the number of insertion/removal cycles increased, removal torques tended to be lower. It was concluded that mechanical loading increased removal torque of loaded abutments in comparison with unloaded abutments, and removal torque values tended to decrease as the number of insertion/removal cycles increased.
机译:目的:开发内部锥形连接以改善生物力学性能并减少在其他植入物连接系统中发现的机械问题。这项研究的目的是评估机械载荷和重复的插入/拔出循环对带有内部锥形连接的基台扭矩损失的影响。材料与方法:使用了两种类型的68个圆锥形种植体和68个基台。他们分为四组:第1组和第3组使用实心基台,第2组和第4组使用两件式基台。在第1组和第2组中,仅安装和卸载了基台。测量了扭矩输入和扭矩输出值。在第3组和第4组中,安装,机械加载和卸载基台。测量了扭矩输入和扭矩输出值。在机械载荷下,两件式基台被摩擦锁定在植入物中。因此,将第4组的数据分类为两个子组(4a:松开固定螺钉所需的扭矩输出值; 4b:从种植体上移除基台所需的扭矩输出值)。每个植入物/基台组件执行十次插入/移除循环。用混合线性模型分析数据(P <或= 0.05)。结果:4a和2组的扭矩损失较高(超过30%的损失),其次是第1组(10.5%的损失),第3组(5.4%的损失)和4b组(39%的扭矩增加)。所有结果均显着不同。随着插入/移除循环次数的增加,移除扭矩趋于降低。结论是,与未加载的基台相比,机械加载增加了已加载的基台的移除扭矩,并且随着插入/移除循环次数的增加,移除扭矩值趋于降低。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号