Differences in respiratory parameters during continuous positive airway pressure and pressure support ventilation in infants and children.

机译:婴幼儿持续气道正压通气和压力支持通气时呼吸参数的差异。

获取原文
获取原文并翻译 | 示例

摘要

The extubation criteria of pressure support ventilation (PSV) in infants and children were not yet established. We studied the differences in respiratory parameters during continuous positive airway pressure (CPAP) using a constant flow type ventilator and PSV using a demand valve type ventilator. Nineteen children (1.9+/-2.9 years old) who were ready to extubate were studied. All patients had recovered from their respiratory failure and had finished the weaning process of the ventilatory support. They were scheduled for extubation on the next day when their ventilatory mode had attained to a PSV of 3 cmH2O with a positive end-expiratory pressure (PEEP) of 3 cmH2O. On the extubation day, tidal volume (TV) and respiratory frequency (RR) were measured with a respiratory monitor at two modes (CPAP of 3 cmH2O and PSV), and the duty ratio (DR) and mean inspiratory flow (MF) were calculated. The sequence of the ventilatory mode was random. No case required reintubation. TV was 61.6+/-54.9 during CPAP and 67.7+/-61.4 ml during PSV, and RR was 38.5+/-10.6 and 37.1+/-8.8 beats/min., respectively. DR was 0.382+/-0.067 and 0.359+/-0.085, and MF was 96.6+/-78.3 and 101.0+/-69.0 ml/sec., respectively. The measured parameters and calculated values showed no significant difference between CPAP and PSV. It was found that the respiratory parameters were almost the same with CPAP and PSV immediately before the extubation, and the previous extubation criteria of CPAP can be used.
机译:尚未建立婴幼儿压力支持通气(PSV)的拔管标准。我们研究了使用恒定流量型呼吸机持续持续气道正压通气(CPAP)和使用需求阀型呼吸机进行PSV时呼吸参数的差异。研究了准备拔管的19名儿童(1.9 +/- 2.9岁)。所有患者均已从呼吸衰竭中恢复过来,并完成了呼吸支持的断奶过程。当他们的通气模式达到PSV为3 cmH2O且呼气末正压(PEEP)为3 cmH2O时,他们计划在第二天拔管。在拔管当天,使用呼吸监测仪以两种模式(CPAP为3 cmH2O和PSV)测量潮气量(TV)和呼吸频率(RR),并计算占空比(DR)和平均吸气量(MF) 。通气模式的顺序是随机的。无需重新插管。 CPAP期间的TV为61.6 +/- 54.9 ml,PSV期间的TV为67.7 +/- 61.4 ml,RR分别为38.5 +/- 10.6和37.1 +/- 8.8次/分钟。 DR为0.382 +/- 0.067和0.359 +/- 0.085,MF为96.6 +/- 78.3和101.0 +/- 69.0ml / sec。实测参数和计算值显示CPAP和PSV之间无显着差异。发现在拔管之前,CPAP和PSV的呼吸参数几乎相同,可以使用以前的CPAP拔管标准。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号