首页> 外文期刊>Journal of magnetic resonance imaging: JMRI >STIR vs. T1-weighted fat-suppressed gadolinium-enhanced MRI of bone marrow edema of the knee: computer-assisted quantitative comparison and influence of injected contrast media volume and acquisition parameters.
【24h】

STIR vs. T1-weighted fat-suppressed gadolinium-enhanced MRI of bone marrow edema of the knee: computer-assisted quantitative comparison and influence of injected contrast media volume and acquisition parameters.

机译:STIR与T1加权脂肪抑制的g增强MRI膝关节骨髓水肿:计算机辅助定量比较以及注射的造影剂体积和采集参数的影响。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: To compare short tau inversion recovery (STIR) and T1-weighted (T1w) gadolinium (Gd)-enhanced fat-suppressed MRI of bone marrow edema (BME) of the knee, and investigate the influence of injected contrast media volume and variation of major acquisition parameters on apparent BME volume and signal contrast. MATERIALS AND METHODS: STIR and T1w Gd-enhanced fat-suppressed images were obtained from 30 patients with BME of the knee. Two groups of patients were examined with different MR scanners, acquisition parameters, and contrast media volumes. For both sequences, BME volume and signal contrast were assessed by computer-assisted quantification, and were compared through their arithmetic means and correlation coefficients (r(2)). The injected contrast media volume was also correlated with BME volume and signal contrast differences between sequences. RESULTS: A strong correlation between the STIR and Gd-enhanced T1w images was found for BME volume (r(2) = 0.96-0.99) and BME signal contrast (r(2) = 0.86-0.94). Despite the differences in MR acquisition parameters and injected contrast media volume, both sequences depicted an almost identical BME volume in both groups. Contrast media volume showed a moderate correlation (r(2) = 0.40) with BME volume differences. CONCLUSION: STIR is the optimum method for determining the size and signal contrast of BME. The injected contrast media volume appears to have only a limited influence on apparent BME volume.
机译:目的:比较短期tau反转恢复(STIR)和T1加权(T1w)lin(Gd)增强的膝关节骨髓水肿(BME)的脂肪抑制MRI,并研究注射造影剂的量和变化的影响采集参数对表观BME体积和信号对比度的影响。材料与方法:从30例膝关节BME患者中获得了STIR和T1w Gd增强的脂肪抑制图像。两组患者使用不同的MR扫描仪,采集参数和造影剂量进行检查。对于这两个序列,BME的体积和信号对比度均通过计算机辅助量化进行评估,并通过算术平均值和相关系数进行比较(r(2))。注入的造影剂体积也与BME体积和序列之间的信号对比度差异相关。结果:发现BIR体积(r(2)= 0.96-0.99)和BME信号对比度(r(2)= 0.86-0.94)与STIR和Gd增强T1w图像之间存在很强的相关性。尽管MR采集参数和注入的造影剂体积有所不同,但这两个序列在​​两组中均显示了几乎相同的BME体积。造影剂体积显示与BME体积差异具有中等相关性(r(2)= 0.40)。结论:STIR是确定BME大小和信号对比度的最佳方法。注入的造影剂体积似乎仅对表观BME体积具有有限的影响。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号