首页> 外文期刊>Journal of magnetic resonance >An apparatus for pulsed ESR and DNP experiments using optically excited triplet states down to liquid helium temperatures
【24h】

An apparatus for pulsed ESR and DNP experiments using optically excited triplet states down to liquid helium temperatures

机译:一种用于ESR和DNP脉冲实验的设备,使用光激发三重态到低至液氦温度

获取原文
获取原文并翻译 | 示例
       

摘要

In standard Dynamic Nuclear Polarization (DNP) electron spins are polarized at low temperatures in a strong magnetic field and this polarization is transferred to the nuclear spins by means of a microwave field. To obtain high nuclear polarizations cryogenic equipment reaching temperatures of 1 K or below and superconducting magnets delivering several Tesla are required. This equipment strongly limits applications in nuclear and particle physics where beams of particles interact with the polarized nuclei, as well as in neutron scattering science. The problem can be solved using short-lived optically excited triplet states delivering the electron spin. The spin is polarized in the optical excitation process and both the cryogenic equipment and magnet can be simplified significantly. A versatile apparatus is described that allows to perform pulsed dynamic nuclear polarization experiments at X-band using short-lived optically excited triplet sates. The efficient ~4He flow cryostat that cools the sample to temperatures between 4 K and 300 K has an optical access with a coupling stage for a fiber transporting the light from a dedicated laser system. It is further designed to be operated on a neutron beam. A combined pulse ESR/DNP spectrometer has been developed to observe and characterize the triplet states and to perform pulse DNP experiments. The ESR probe is based on a dielectric ring resonator of 7 mm inner diameter that can accommodate cubic samples of 5 mm length needed for neutron experiments. NMR measurements can be performed during DNP with a coil integrated in the cavity. With the presented apparatus a proton polarization of 0.5 has been achieved at 0.3 T.
机译:在标准动态核极化(DNP)中,电子自旋在低温下在强磁场中极化,并且该极化通过微波场转移到核自旋。为了获得高核极化,需要达到1 K或更低温度的低温设备以及输送几个特斯拉的超导磁体。该设备极大地限制了在粒子束与极化核相互作用的核和粒子物理学中的应用,以及在中子散射科学中的应用。可以使用短时的光学激发三重态传递电子自旋来解决该问题。自旋在光激发过程中被极化,并且可以大大简化低温设备和磁体。描述了一种通用设备,该设备允许使用短暂的光激发三重态在X波段执行脉冲动态核极化实验。高效的〜4He流动低温恒温器将样品冷却至4 K至300 K之间,具有一个光学通道,该通道带有一个耦合台,用于传输来自专用激光系统的光。它被进一步设计为在中子束上运行。已开发出组合式脉冲ESR / DNP光谱仪,以观察和表征三重态并进行脉冲DNP实验。 ESR探头基于内径为7 mm的电介质环形谐振器,可以容纳中子实验所需的5 mm长的立方样品。可以在DNP期间使用集成在腔体中的线圈进行NMR测量。使用本发明的装置,在0.3 T下已经实现了0.5的质子极化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号