首页> 外文期刊>Journal of Microbiological Methods >Comparative evaluation of 2,3-bis [2-methyloxy-4-nitro-5-sulfophenyl]-2H-tetrazolium-5-carboxanilide (XTT) and 2-(2-methoxy-4-nitrophenyl)-3-(4-nitrophenyl)-5-(2, 4-disulfophenyl)-2H-tetrazolium, monosodium salt (WST-8) rapid colorimetric assays for
【24h】

Comparative evaluation of 2,3-bis [2-methyloxy-4-nitro-5-sulfophenyl]-2H-tetrazolium-5-carboxanilide (XTT) and 2-(2-methoxy-4-nitrophenyl)-3-(4-nitrophenyl)-5-(2, 4-disulfophenyl)-2H-tetrazolium, monosodium salt (WST-8) rapid colorimetric assays for

机译:2,3-双[2-甲氧基-4-硝基-5-磺苯基] -2H-四唑-5-甲酰苯胺(XTT)和2-(2-甲氧基-4-硝基苯基)-3-(4-硝基苯基)-5-(2,4-二磺基苯基)-2H-四唑鎓,一钠盐(WST-8)快速比色测定

获取原文
获取原文并翻译 | 示例
           

摘要

A new generation of water soluble tetrazolium salts have recently become available and in this study we compared a colorimetric assay developed using one of these salts, 2-(2-methoxy-4-nitrophenyl)-3-(4-nitrophenyl)-5-(2, 4-disulfophenyl)-2H-tetrazolium, monosodium salt (WST-8), with a previously developed 2,3-bis [2-methyloxy-4-nitro-5-sulfophenyl]-2H-tetrazolium-5-carboxanilide (XTT) colorimetric assay to determine which agent is most suitable for use as a colorimetric indicator in susceptibility testing. The MICs of 6 antibiotics were determined for 33 staphylococci using both colorimetric assays and compared with those obtained using the British Society for Antimicrobial Chemotherapy reference broth microdilution method. Absolute categorical agreement between the reference and test methods ranged from 79% (cefuroxime) to 100% (vancomycin) for both assays. No minor or major errors occurred using either assay with very major errors ranging from zero (vancomycin) to seven (cefuroxime). Analysis of the distribution of differences in the log(2) dilution MIC results revealed overall agreement, within the accuracy limits of the standard test (+/-1 log(2) dilution), using the XTT and WST-8 assays of 98% and 88%, respectively. Further studies on 31 ESBL-producing isolates were performed using the XTT method with absolute categorical agreement ranging from 87% (nitrofurantoin) to 100% (ofloxacin and meropenem). No errors were noted for either ofloxacin or meropenem with overall agreement of 91%. The data suggests that XTT is more reliable and accurate than WST-8 for use in a rapid antimicrobial susceptibility test.
机译:新一代水溶性四唑鎓盐最近已经上市,在这项研究中,我们比较了使用其中一种盐2-(2-甲氧基-4-硝基苯基)-3-(4-硝基苯基)-5-开发的比色测定法。 (2,4-二磺基苯基)-2H-四唑鎓钠盐(WST-8),与先前开发的2,3-双[2-甲氧基-4-硝基-5-磺基苯基] -2H-四唑鎓-5-羧苯胺(XTT)比色测定法,以确定哪种试剂最适合用作药敏测试中的比色指示剂。使用两种比色法测定了6种抗生素的MIC,确定了33种葡萄球菌,并将其与使用英国抗微生物化学疗法协会参考肉汤微量稀释法获得的MIC进行了比较。对于两种测定,参考方法和测试方法之间的绝对绝对分类范围为79%(头孢呋辛)至100%(万古霉素)。两种测定法均未发生轻微或重大错误,重大错误的范围从零(万古霉素)到七个(头孢呋辛)。使用98%的XTT和WST-8分析,对log(2)稀释MIC结果中差异分布的分析表明,在标准测试(+/- 1 log(2)稀释)的准确度范围内,总体一致。和88%分别。使用XTT方法对31种产生ESBL的菌株进行了进一步的研究,其绝对分类一致性为87%(呋喃妥因)至100%(氧氟沙星和美罗培南)。氧氟沙星或美罗培南均未发现错误,总体同意率为91%。数据表明,在快速抗菌药敏试验中,XTT比WST-8更可靠,更准确。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号