We report systematic measurements of the response of a Vibrating Wire Resonator (VWR) in normal and superfluid liquid 3He. Special attention has been paid to the hydrodynamic regime of the superfluid B-phase, where the response parameters of the VWR do not follow a simple law. We show that a simple interpolation between the region where first order slip-corrections can be applied and the ballistic regime is insufficient. Measuring an empirical effective viscosity, we propose a temperature calibration method which allows the use of VWRs as a secondary thermometer at intermediate and high pressures in the temperature range 0.2 T_c < T < 50 mK.
机译:我们报告了在正常和超流体液体3He中振弦谐振器(VWR)响应的系统测量。已经特别注意了超流体B相的流体力学状态,其中VWR的响应参数不遵循简单的定律。我们表明,在可以应用一阶滑移校正的区域与弹道之间的简单插值是不够的。通过测量经验有效粘度,我们提出了一种温度校准方法,该方法允许在0.2 T_c