Liquid scintillating phantoms have been proposed as a means to perform real-time 3D dosimetry for proton therapy treatment plan verification. We have studied what effect radiation damage to the scintillator will have upon this application. We have performed measurements of the degradation of the light yield and optical attenuation length of liquid scintillator and water-based liquid scintillator after irradiation by 201MeV proton beams that deposited doses of approximately 52 Gy, 300 Gy, and 800 Gy in the scintillator. Liquid scintillator and water-based liquid scintillator (composed of 5% scintillating phase) exhibit light yield reductions of 1.74±0.55% and 1.31± 0.59% after = 800 Gy of proton dose, respectively. Whilst some increased optical attenuation was observed in the irradiated samples, the measured reduction to the light yield is also due to damage to the scintillation light production. Based on our results and conservative estimates of the expected dose in a clinical context, a scintillating phantom used for proton therapy treatment plan verification would exhibit a systematic light yield reduction of approximately 0.1% after a year of operation.
机译:已经提出液体闪烁体模作为执行实时3D剂量测定以质子疗法治疗计划验证的方法。我们已经研究了对闪烁器的辐射损伤将对该应用产生什么影响。我们对201MeV质子束辐照后在闪烁体中沉积约52 Gy,300 Gy和800 Gy剂量的液体闪烁体和水基液体闪烁体的光通量和光衰减长度的衰减进行了测量。在= 800 Gy的质子剂量后,液体闪烁体和水基液体闪烁体(由5%闪烁相组成)的光产率降低分别为1.74±0.55%和1.31±0.59%。尽管在被辐照的样品中观察到一些光学衰减的增加,但是所测得的光通量的降低也是由于对闪烁光产生的损害。根据我们的结果和对临床预期剂量的保守估计,用于质子治疗治疗计划验证的闪烁体模在手术一年后将显示出约0.1%的系统光输出降低。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号