Biogenic amines and amino acids are widely characterized in the pathways representing neurotransmission. Although several analytical methodologies have been used to detect specific target molecules in relevant fluids such as cerebrospinal fluid (CSF), multiple assays must be used to survey the primary pathways involved. This article describes the development of a GC/MS/MS method capable of analyzing up to 43 analytes (representing 20 amino acids and more than seven neurochemical pathways) from a single 50 mu I CSF sample. In this procedure, a CSF sample is first treated with acetonitrile to precipitate proteins. The dried sample is then derivatized with a mixture of 2,2,3,3,3-pentafluoro-l-propanol and pentafluoropropionic acetic anhydride to replace all active hydrogen atoms with fluorine-containing groups. Due to the concentration difference between amino acids and neurotransmitters, these two compound classes are analyzed in separate injections of the same derivatized extract. The total run time for each injection is approximately 15-20 min. An essential feature of the method is the use of argon as a reagent gas for electron capture chemical ionization (ECCI), as the use of the more traditional gas (methane) lacked sufficient durability to be considered for use with the present instrumentation. This article describes the development of this method including a detailed investigation of the chemical ionization conditions used. The resultant conditions allow for the profiling of biogenic amines (e.g. serotonin, norepinephrine, and dopamine) in the low picogram per milliliter range.
机译:生物胺和氨基酸在代表神经传递的途径中被广泛表征。尽管已使用几种分析方法来检测相关流体(例如脑脊液(CSF))中的特定目标分子,但必须使用多种测定方法来调查涉及的主要途径。本文介绍了一种GC / MS / MS方法的开发,该方法能够从一个50μI CSF样品中分析多达43种分析物(代表20个氨基酸和七个以上的神经化学途径)。在此程序中,首先用乙腈处理CSF样品以沉淀蛋白质。然后将干燥的样品用2,2,3,3,3-五氟-1-丙醇和五氟丙酸乙酸酐的混合物衍生化,以用含氟基团代替所有活性氢原子。由于氨基酸和神经递质之间的浓度差异,在同一衍生提取物的单独进样中分析了这两种化合物。每次注射的总运行时间约为15-20分钟。该方法的基本特征是使用氩气作为电子捕获化学电离(ECCI)的反应气,因为使用更传统的气体(甲烷)缺乏足够的耐久性,无法考虑与本仪器一起使用。本文介绍了这种方法的发展,包括对所用化学电离条件的详细研究。所产生的条件允许将生物胺(例如5-羟色胺,去甲肾上腺素和多巴胺)的轮廓分析定在每皮克低皮克范围内。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号