首页> 外文期刊>Journal of manipulative and physiological therapeutics: JMPT >Validity of infrared thermal measurements of segmental paraspinal skin surface temperature.
【24h】

Validity of infrared thermal measurements of segmental paraspinal skin surface temperature.

机译:红外热测量节段性椎旁皮肤表面温度的有效性。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVE: The purpose of this study was to evaluate the validity of thermal measurements by infrared camera thermometry. METHODS: Seventeen subjects underwent a 30-minute acclimatizing period in a controlled environment room. Thermal recordings were executed at the levels of C4 and L4. Fifteen recordings per segment were acquired in an alternating mode that always started at L4. Each subject was required to participate on 5 occasions. The exclusion criteria for the subjects included the following: no inflammatory disease or fever, no consumption of beverages containing caffeine, and no participation in physical activity 2 hours before the recording session; female subjects could not be menstruating on a day of recording. RESULTS: A total of 2550 recordings for the cervical area and the lumbar area was recorded. Strong significant correlations were found for the left (r = .77) and right (r = .71) lumbar sections (P < .0001) whereas weaker significant correlations were observed for the left (r = .56) and right (r = .63) cervical areas (P < .0001). The limits of agreement (Bland-Altman) showed good relationships but poor interchangeability. CONCLUSIONS: In this study, the infrared cameras showed that they were valid tools in a controlled environment; however, the technique for the cervical measurements needs to be reassessed.
机译:目的:本研究的目的是评估红外热像仪进行热测量的有效性。方法:17名受试者在环境受控的房间内进行了30分钟的适应训练。在C4和L4级别执行热记录。每段十五个记录是以交替模式获取的,该模式始终从L4开始。每个受试者必须参加5次。受试者的排除标准包括以下内容:没有炎症或发烧,没有食用含咖啡因的饮料,并且在录音前2小时没有参加体育锻炼;女性对象在录制当天不能进行月经。结果:总共记录了2550例宫颈区域和腰部区域的记录。左(r = .77)和右(r = .71)腰椎切面(P <.0001)的相关性很强,而左(r = .56)和右(r = 0.05)的相关性较弱。 .63)宫颈区域(P <.0001)。协议限制(Bland-Altman)显示出良好的关系,但互换性较差。结论:在这项研究中,红外热像仪表明它们在受控环境中是有效的工具。然而,需要重新评估宫颈测量技术。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号