...
首页> 外文期刊>Journal of interventional cardiology >Transcatheter closure of secundum atrial septal defect with a new self-expanding nitinol double disk device (Amplatzer device): experience in Nanjing.
【24h】

Transcatheter closure of secundum atrial septal defect with a new self-expanding nitinol double disk device (Amplatzer device): experience in Nanjing.

机译:新型自扩张镍钛合金双盘装置(Amplatzer装置)经导管封闭继发性房间隔缺损:在南京的经验。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

PURPOSE: Various devices have been developed for the transcatheter closure of secundum atrial septal defect (ASD II) to avoid the morbidity, discomfort, and thoracotomy scar associated with surgical closure. The purpose of this study was to evaluate the safety and efficacy of the Amplatzer septal occluder for transcatheter closure of ASD II. PATIENTS AND METHODS: Only patients who were clinically diagnosed with ASD II were selected. The anatomy of ASD had to meet certain echocardiographic criteria. Under the guidance of echocardiography and fluoroscopy, the implantation of the device was accomplished as recommended by the manufacturer. RESULTS: Thirty patients (median age 18.4 years) with an ASD II underwent transcatheter closure. Procedure time ranged from 30-200 minutes and fluoroscopy time from 10-50 minutes. The diameter of the ASD measured by echocardiography ranged from 13-25 mm, while both the stretched diameters of the ASDs and the sizes of the devices ranged from 18-34 mm. The successful placement rate was 100%. The residual shunt rate was 100% immediately after device implantation and 10% after 24 hours. After 3 months, 3.3% of the patients had a (trivial) residual shunt. The device did not affect the surrounding structures of ASD. No embolization of the device occurred. CONCLUSION: The Amplatzer device designed for the closure of ASD II can be implanted easily and also is retrievable. Due to a low ratio of residual shunt and few complications, this device is a good choice for transcatheter closure of ASD II. Long-term follow-up will be required for widespread clinical use.
机译:目的:已开发出多种设备用于经导管封闭继发性房间隔缺损(ASD II),以避免与手术封闭相关的并发症,不适和开胸疤痕。这项研究的目的是评估Amplatzer隔室封堵器对ASD II经导管闭合的安全性和有效性。患者与方法:仅选择经临床诊断为ASD II的患者。 ASD的解剖必须满足某些超声心动图标准。在超声心动图和荧光检查的指导下,设备的植入已按照制造商的建议完成。结果:30例ASD II患者(中位年龄为18.4岁)接受了经导管封闭术。程序时间为30-200分钟,而透视检查时间为10-50分钟。通过超声心动图测量的ASD直径范围为13-25 mm,而ASD的拉伸直径和设备尺寸均为18-34 mm。成功放置率是100%。器件植入后,残余分流率为100%,24小时后为10%。 3个月后,有3.3%的患者残余残流。该设备没有影响ASD的周围结构。没有发生装置的栓塞。结论:设计用于闭合ASD II的Amplatzer装置可以轻松植入,并且可以取回。由于残余分流率低且并发症少,因此该设备是经导管封闭ASD II的理想选择。广泛的临床应用将需要长期随访。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号