首页> 外文期刊>Journal of industrial and engineering chemistry >Zinc(II) modified carbon paste electrodes based on self-assembled mercapto compounds-gold-nanoparticles for its determination in water samples
【24h】

Zinc(II) modified carbon paste electrodes based on self-assembled mercapto compounds-gold-nanoparticles for its determination in water samples

机译:基于自组装巯基化合物-金-纳米粒子的锌(II)修饰碳糊电极,用于水样品中的测定

获取原文
获取原文并翻译 | 示例
           

摘要

In the present study newly developed potentiometric sensors for determination of zinc(II) are presented. The proposed potentiometric method was based on the fabrication of modified carbon paste (MCPE; electrode X) and modified gold nanoparticles-carbon paste (GNPs-CPE; electrode IX) sensors. A mercapto compound of l,4-bis(5-mercaptopentyloxy)-benzene (BMPB) alone or self-assembled on gold nanoparticles was used as modifier to construct electrode (X) and electrode (IX) sensors, respectively. The prepared electrodes exhibit Nernstian slope of 29.93 ±0.4 and 26.0 ± 1.02 mV decade~(-1) towards Zn(II) ion over a wide concentration range of 6.8 × 10~(-10) to 2.9 × 10~(-2)and 1.0 × 10~(-7) to 1.0× 10~(-2)mol L~(-1) for electrode (IX) and electrode (X) sensors, respectively. The limit of detection of the electrode (IX) and electrode (X) sensors was found to be 6.8 × 10~(-10) and 1.0 × 10~(-7) mol L~(-1) respectively. The potentiometric response of the electrode (IX) and electrode (X) based on GNPs-BMPB and BMPB are independent of pH of test solution in the pH range of 2.5-8.1 and 3-7 with a response time of 6 and 8 s for electrode (IX) and electrode (X) sensors, respectively. The proposed sensors showed fairly good discriminating ability towards Zn(II) ion in comparison with many hard and soft metal ions. Finally, the proposed electrodes were successfully used as indicator electrodes in potentiometric titration of zinc ion with sodium tetraphenylborate (NaTPB) and in direct determination of Zn(II) ion in some water samples. The results obtained compared well with those obtained using atomic absorption spectrometry.
机译:在本研究中,提出了用于测定锌(II)的新开发的电位传感器。所提出的电位计方法基于修饰碳糊(MCPE;电极X)和修饰金纳米颗粒-碳糊(GNPs-CPE;电极IX)传感器的制造。单独或自组装在金纳米颗粒上的1,4-双(5-巯基戊氧基)-苯(BMPB)的巯基化合物用作改性剂,分别构建电极(X)和电极(IX)传感器。制备的电极在6.8×10〜(-10)至2.9×10〜(-2)的宽浓度范围内,对Zn(II)离子的能斯特斜率分别为29.93±0.4和26.0±1.02 mV·十(-1)。对于电极(IX)和电极(X)传感器分别为1.0×10〜(-7)至1.0×10〜(-2)mol L〜(-1)。电极(IX)和电极(X)传感器的检出限分别为6.8×10〜(-10)和1.0×10〜(-7)mol L〜(-1)。在2.5-8.1和3-7的pH范围内,基于GNPs-BMPB和BMPB的电极(IX)和电极(X)的电位响应与测试溶液的pH无关,响应时间分别为6和8 s。电极(IX)和电极(X)传感器。与许多硬质和软质金属离子相比,拟议的传感器对Zn(II)离子具有相当好的区分能力。最终,所提出的电极成功地用作指示电极,用四苯基硼酸钠(NaTPB)滴定锌离子,并直接测定某些水样中的Zn(II)离子。获得的结果与使用原子吸收光谱法获得的结果进行了很好的比较。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号