Hg calibration and conversion systems, which are integral parts of a continuous emission monitor for were designed, produced, and tested. First, both Hg° and Hg~(2+) calibrators showed less than 10X difference between measured and theoretical values. Next, a Hg~(2+) to Hg° thermal converter with a scrubber and heated gas lines showed a conversion efficiency higher than 95%. Finally, the laboratory-prepared Hg converter was tested at a full-scale medical waste incinerator. The Ontario Hydro Method was used for measurement and speciation of Hg. The results showed that the laboratory-prepared Hg converter was highly effective with highest conversion efficiency close to 94%. KMercury;; Hg calibration;; Hg oxidation;; Hg reduction;; CEM;; Medical waste incinerator
机译:汞校准和转换系统是连续排放监测仪不可或缺的一部分,用于设计,生产和测试。首先,Hg°和Hg〜(2+)校准器的测量值与理论值之间的差异小于10倍。接下来,具有洗涤器和加热的气体管线的Hg〜(2+)至Hg°热转化器显示出高于95%的转化效率。最后,在大型医疗废物焚烧炉上对实验室制得的汞转化器进行了测试。安大略水电法用于汞的测量和形态分析。结果表明,实验室制备的汞转化器非常有效,最高转化效率接近94%。 K Mercury ;;汞校准;汞氧化;汞减少; CEM ;;医疗废物焚化炉