首页> 外文期刊>Journal of innovative optical health sciences >Zernike astigmatism and visual performance in myopic eyes by rigid gas permeable contact lenses wear
【24h】

Zernike astigmatism and visual performance in myopic eyes by rigid gas permeable contact lenses wear

机译:刚性透气性隐形眼镜配戴后的近视眼的Zernike散光和视觉性能

获取原文
获取原文并翻译 | 示例
       

摘要

To investigate the effects of rigid-gas-permeable contact lens (RGP-CL) wear on Zernike astigmatism and visual performance in myopic eyes. Methods: A wavefront sensor was used to evaluate Zernike astigmatism for 21 eyes with minimum astigmatism and 18 eyes with moderate astigmatism under three different modes of refractive correction: the RGP-CL, spectacle lens correcting spherical equivalent (SL) and spectacle lens fully correcting spherical error and astigmatism (fSL). Contrast visual acuity was assessed with a VA tester at four contrast levels and two luminance backgrounds. Results: Compared to the SL wear, RGP-CL wear changed the main axis astigmatism (Z _2 ~2) from -0.09 ± 0.34 to 0.34 ± 0.22 for the minimum astigmatism group, while the contrast VA was improved about 0.05 LogMAR (F = 8.06, p < 0.01). For the group with moderate astigmatism, significant reduction in Z 2 2 was found for both fSL wear (t = 4.78, p < 0.001) and RGP-CL wear (t = 6.29, p < 0.0001). The changes in astigmatism were significantly correlated between the fSL and RGP-CL wears (r = 0.897, p < 0.0001 for Z _2~(-2); and r = 0.643, p = 0.004 for Z _2 ~2. Contrast VA was significantly improved for both fSL and RGP-CL wears and the improvements were significantly correlated between each other for all four contrast levels and two backgrounds. Conclusion: RGP-CL wear induces astigmatism for the eyes with minor astigmatism probably due to a correction of corneal astigmatism and thus a manifesting of the lens astigmatism. For the astigmatic eyes, RGP-CL wear has similar effect on correcting astigmatism as the spectacle lens wear with spherical-cylinder correction and also produces similar visual improvement.
机译:研究刚性透气性隐形眼镜(RGP-CL)的佩戴对Zernike散光和近视眼视觉性能的影响。方法:使用波前传感器在三种不同的屈光矫正模式下分别评估RGD-CL,矫正球镜等效值(SL)和完全矫正球镜的Zernike散光,用于21眼最小散光和18眼中度散光。错误和散光(fSL)。用VA测试仪在四个对比水平和两个亮度背景下评估对比视敏度。结果:与SL磨损相比,RGP-CL磨损将最小像散组的主轴像散(Z _2〜2)从-0.09±0.34更改为0.34±0.22,而对比VA改善了约0.05 LogMAR(F = 8.06,p <0.01)。对于中度散光的人群,fSL磨损(t = 4.78,p <0.001)和RGP-CL磨损(t = 6.29,p <0.0001)均显着降低Z 2 2。 fSL和RGP-CL磨损之间的散光变化显着相关(Z _2〜(-2)r = 0.897,p <0.0001; Z _2〜2 r = 0.643,p = 0.004。对比度VA显着结论:RGP-CL的佩戴可引起散光,对轻微散光的眼睛可引起散光,这可能是由于角膜散光和散光的矫正所致。对于散光眼来说,RGP-CL配戴对散光的矫正效果与采用球镜矫正的眼镜配戴具有相似的效果,并且还可以产生类似的视觉改善。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号