Reliability of Concentric, Eccentric and Isometric Knee Extension and Flexion when using the REV9000 Isokinetic Dynamometer

机译:使用REV9000等速测功机时,同心,偏心和等距膝盖伸和屈的可靠性

获取原文
获取原文并翻译 | 示例
       

摘要

The aim of this study was to assess the reliability of isokinetic and ISO knee extensor and flexor muscle strength when using the REV9000 (Technogym) isokinetic dynamometer. Moreover, the reliability of several strength imbalance indices and bilateral ratios were also examined. Twenty-four physically active healthy subjects (age 23±3 years) underwent three testing sessions, two on the same day and a third, 7 days later. All sessions proceeded in the same order: five concentric contractions at 60s-1 followed by an isometric contraction (5 seconds) and five eccentric contractions (60s-1). The results of this study showed a high reproducibility in eccentric (0.95-0.97), concentric (0.95-0.96) and isometric (0.93-0.96), isokinetic strength for knee extensor and flexor muscles, thus indicating that the REV9000 isokinetic dynamometer can be used in future sports performance studies. A low-to-moderate reliability was found in the isokinetic strength bilateral ratios while the Hamstring:Quadricep concentric ratio showed moderate reliability. The highest reliability (>0.90) was observed in the dynamic control ratio (Hamstring eccentric: Quadricep concentric) which consequently confirms that it is a more valid indicator for imbalanced reciprocal parameters and can be used in rehabilitation and sports medicine.
机译:这项研究的目的是评估使用REV9000(Technogym)等速测功机时等速和ISO膝关节伸肌和屈肌力量的可靠性。此外,还检查了几种强度失衡指标和双边比率的可靠性。 24名身体活跃的健康受试者(年龄23±3岁)接受了3次测试,其中两次在同一天,第三次在7天后。所有阶段均以相同的顺序进行:在60s-1发生五次同心收缩,然后是等距收缩(5秒)和五次偏心收缩(60s-1)。这项研究的结果显示偏心(0.95-0.97),同心(0.95-0.96)和等距(0.93-0.96),膝部伸肌和屈肌的等速强度具有较高的可重复性,因此表明可以使用REV9000等速测力计在未来的运动表现研究中。在等速强度双侧比率中发现低至中度的可靠性,而Ham绳肌:四头肌同心度比率显示出中等的可靠性。在动态控制比(H绳肌偏心:Quadricep同心)中观察到最高的可靠性(> 0.90),因此证实了它是用于相互参数不平衡的更有效的指标,可用于康复和运动医学。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号