Confirmatory assays for immunogenicity testing typically involve testing a sample in the presence or absence of excess drug. A decrease in assay signal in the presence of drug is taken to indicate the presence of anti-drug antibodies (ADAb) and the sample is confirmed positive. While there is widespread acceptance of the principle, there are currently no published guidelines for determining how much the signal should be reduced for a sample to be confirmed positive. In this report we address this issue using a novel approach employing a Student's t-test. The basic premise is to assess if an observed decrease in signal in the presence of drug is greater than what might be expected to occur as a result of the normal variation in the system. A key component of the method involves being able to capture and measure all of the normal variation. This requires a modification of commonly employed methods of sample preparation. We validated the method and tested samples from a clinical study. In addition, we reanalyzed the data to see what would have been the outcome had we used two other common approaches for confirmatory assays, one based on a minimum percent decrease in signal to confirm positivity (arbitrarily set at 25%), and one requiring a minimum drop in signal, set by a low quality control (QC) sample. The t-test approach proved superior over a wide range of assay signals and appeared to result in fewer false negatives.
机译:用于免疫原性测试的确证分析通常涉及在存在或不存在过量药物的情况下测试样品。药物存在下测定信号的降低表示存在抗药物抗体(ADAb),并且样品被确认为阳性。尽管该原理已被广泛接受,但目前尚无已发布的指南来确定应减少多少信号才能确认样品为阳性。在本报告中,我们采用一种采用学生t检验的新颖方法来解决此问题。基本前提是评估在药物存在下观察到的信号下降是否大于系统正常变化可能导致的信号下降。该方法的关键组成部分在于能够捕获和测量所有正常变化。这需要修改常用的样品制备方法。我们验证了该方法并测试了来自临床研究的样品。此外,我们重新分析了数据,以了解如果我们使用其他两种常见方法进行确认性分析,结果将是什么,一种基于信号确认阳性的最小百分比降低(任意设置为25%),另一种则需要由低质量控制(QC)样本设置的最小信号下降。经证明,t检验方法在各种分析信号中均具有优越性,并且似乎可以减少假阴性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号