...
首页> 外文期刊>Journal of Geophysical Research, D. Atmospheres: JGR >Intercomparison of spectroradiometers and Sun photometers for the determination of the aerosol optical depth during the VELETA-2002 field campaign
【24h】

Intercomparison of spectroradiometers and Sun photometers for the determination of the aerosol optical depth during the VELETA-2002 field campaign

机译:在VELETA-2002野战期间分光辐射计和太阳光度计的比对,用于确定气溶胶光学深度

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

In July 2002 the VELETA-2002 field campaign was held in Sierra Nevada (Granada) in the south of Spain. The main objectives of this field campaign were the study of the influence of elevation and atmospheric aerosols on measured UV radiation. In the first stage of the field campaign, a common calibration and intercomparison between Licor-1800 spectroradiometers and Cimel-318 Sun photometers was performed in order to assess the quality of the measurements from the whole campaign. The intercomparison of the Licor spectroradiometers showed, for both direct and global irradiances, that when the comparisons were restricted to the visible part of the spectrum the deviations were within the instruments' nominal accuracies which allows us to rely on these instruments for measuring physical properties of aerosols at the different measurement stations. A simultaneous calibration on AOD data was performed for the Cimel-318 Sun photometers. When a common calibration and methodology was applied, the deviation was lowered to much less than 0.01 for AOD. At the same time an intercomparison has been made between the AOD values given by the spectroradiometers and the Sun photometers, with deviations obtained from 0.01 to 0.03 for the AOD in the visible range, depending on the channel. In the UVA range, the AOD uncertainty was estimated to be around 0.02 and 0.05 for Cimel and Licor respectively. In general the experimental differences were in agreement with this uncertainty estimation. In the UVB range the AOD measurements should not be used due to maximum instrumental uncertainties.
机译:2002年7月,在西班牙南部的内华达山脉(格拉纳达)举行了VELETA-2002野战。该野外活动的主要目标是研究海拔和大气气溶胶对测得的紫外线辐射的影响。在现场战役的第一阶段,进行了Licor-1800分光辐射仪和Cimel-318太阳光度计之间的通用校准和比对,以评估整个战役的测量质量。 Licor分光光度计的比较表明,对于直接和全局辐照度,当比较仅限于光谱的可见部分时,偏差都在仪器的名义精度范围内,这使我们能够依靠这些仪器来测量仪器的物理性质。不同测量站的气溶胶。对于Cimel-318 Sun光度计,同时对AOD数据进行了校准。当使用通用的校准和方法时,AOD的偏差降低到小于0.01。同时,在光谱辐射仪和太阳光度计给出的AOD值之间进行了比较,根据通道的不同,可见光范围内AOD的偏差在0.01到0.03之间。在UVA范围内,对于Cimel和Licor,AOD不确定度估计分别约为0.02和0.05。通常,实验差异与该不确定性估计相符。由于最大的仪器不确定性,在UVB范围内不应使用AOD测量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号