Measured electric and magnetic fields from an unusual cloud-to-ground lightning flash containing two positive strokes followed by four negative strokes

机译:来自异常的云对地闪电的测量电场和磁场,该闪电包含两个正冲程,然后是四个负冲程

获取原文
获取原文并翻译 | 示例
           

摘要

We present electric and magnetic fields measured at multiple stations between about 300 and 800 m of a cloud-to-ground "bipolar" lightning flash containing two initial positive strokes, separated in time by 53 ms and striking ground at two locations separated by about 800 m, followed by four negative strokes that traversed the same path as the second positive stroke. The leader electric field durations for the positive first, positive second, and negative third strokes were about 120 ms, 35 ms, and 1 ms, respectively. The first-stroke leader electric field changes measured at five stations ranged from about +16 to +35 kV/m, the second stroke +8 to +13 kV/m, and the third stroke —0.9 to —1.8 kV/m (atmospheric electricity sign convention). The microsecond-scale return stroke waveforms of the first and second (positive) strokes exhibited a similar "slow-front/ fast-transition" to those observed for close negative first strokes. The peak rate-of-change of the positive first stroke electric field normalized to 100 km was about 20 V m-1 is-1, similar to the values observed for close negative first strokes. The positive second stroke was followed by a long continuing current of duration at least 400 ms, while the positive first stroke had a total current duration of only about 1 ms. All four negative strokes were followed by long continuing current, with durations ranging from about 70 ms to about 230 ms. The overall flash duration was about 1.5 s.
机译:我们介绍了在多个站点测得的电场和磁场,这些站点在大约300到800 m的云对地“双极”闪电中,包含两个初始正冲程,时间间隔为53 ms,在两个位置撞击地面,间隔为约800 m,然后是四个负笔画,它们与第二个正笔画穿越了相同的路径。正的第一,正的第二和负的第三冲程的引导电场持续时间分别约为120 ms,35 ms和1 ms。在五个站点测得的第一次冲程前导电场变化范围为大约+16至+35 kV / m,第二次冲程为+8至+13 kV / m,第三次冲程为-0.9至-1.8 kV / m(大气)电力标志惯例)。第一和第二个(正)笔画的微秒级返回笔画波形显示出与接近负的第一笔画相似的“慢前/快转变”。归一化为100 km的正第一冲程的峰值变化率约为20 V m-1 is-1,类似于接近负负第一冲程的观测值。在第二个正冲程之后,持续持续至少400 ms的持续电流,而第一个正冲程则具有大约1 ms的总电流持续时间。所有四个负冲程之后都伴随着持续的长电流,持续时间范围从大约70毫秒到大约230毫秒。整个闪光持续时间约为1.5 s。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号