...
首页> 外文期刊>Journal of electromyography and kinesiology: Official journal of the International Society of Electrophysiological Kinesiology >Investigation of 3D glenohumeral displacements from 3D reconstruction using biplane X-ray images: Accuracy and reproducibility of the technique and preliminary analysis in rotator cuff tear patients
【24h】

Investigation of 3D glenohumeral displacements from 3D reconstruction using biplane X-ray images: Accuracy and reproducibility of the technique and preliminary analysis in rotator cuff tear patients

机译:使用双翼X射线图像从3D重建中调查3D肱骨移位的技术:该技术的准确性和可重复性以及肩袖撕裂患者的初步分析

获取原文
获取原文并翻译 | 示例
           

摘要

Rotator cuff (RC) tears may be associated with increased glenohumeral instability; however, this instability is difficult to quantify using currently available diagnostic tools. Recently, the three-dimensional (3D) reconstruction and registration method of the scapula and humeral head, based on sequences of low-dose biplane X-ray images, has been proposed for glenohumeral displacement assessment. This research aimed to evaluate the accuracy and reproducibility of this technique and to investigate its potential with a preliminary application comparing RC tear patients and asymptomatic volunteers. Accuracy was assessed using CT scan model registration on biplane X-ray images for five cadaveric shoulder specimens and showed differences ranging from 0.6 to 1.4 mm depending on the direction of interest. Intra-and interobserver reproducibility was assessed through two operators who repeated the reconstruction of five subjects three times, allowing defining 95% confidence interval ranging from +/- 1.8 to +/- 3.6 mm. Intraclass correlation coefficient varied between 0.84 and 0.98. Comparison between RC tear patients and asymptomatic volunteers showed differences of glenohumeral displacements, especially in the superoinferior direction when shoulder was abducted at 20 degrees and 45 degrees. This study thus assessed the accuracy of the low-dose 3D biplane X-ray reconstruction technique for glenohumeral displacement assessment and showed potential in biomechanical and clinical research. (C) 2015 Elsevier Ltd. All rights reserved.
机译:肩袖撕裂(RC)撕裂可能与肱骨肱骨不稳定性增加有关。但是,使用当前可用的诊断工具很难量化这种不稳定性。最近,已提出了基于低剂量双平面X射线图像序列的肩the骨和肱骨头的三维(3D)重建和配准方法,用于评估肱骨肱骨位移。这项研究旨在评估该技术的准确性和可重复性,并通过比较RC撕裂患者和无症状志愿者的初步应用研究其潜力。使用CT扫描模型配准在五个尸体肩部标本的双翼X射线图像上评估准确性,结果显示,根据感兴趣的方向,差异在0.6到1.4 mm之间。观察者之间和观察者之间的可重复性是由两名操作员评估的,该操作员重复了五次受试者的重建,重复了三次,确定了95%的置信区间,范围为+/- 1.8至+/- 3.6 mm。类内相关系数在0.84和0.98之间变化。 RC泪液患者和无症状志愿者之间的比较显示,肱肱骨移位不同,尤其是在20度和45度绑扎肩膀时在上下方向。因此,这项研究评估了低剂量3D双平面X射线重建技术在肱骨肱骨位移评估中的准确性,并显示了在生物力学和临床研究中的潜力。 (C)2015 Elsevier Ltd.保留所有权利。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号