Retinal nerve fiber layer imaging with spectral-domain optical coherence tomography: Effect of multiple B-scan averaging on RNFL measurement

机译:光谱域光学相干断层扫描成像的视网膜神经纤维层成像:多次B扫描平均对RNFL测量的影响

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: To determine the effect of multiple B-scan averaging on retinal nerve fiber layer (RNFL) thickness measurement taken with a spectral-domain optical coherence tomographer (OCT). METHODS: Twenty-five normal individuals and 29 patients with glaucoma were examined. One eye was selected randomly of each participant for circumpapillary RNFL scanning by the Spectralis OCT (Heidelberg Engineering, Heidelberg, GmbH, Dossenheim, Germany). Three sets of OCT image series comprising 2, 8, and 16 consecutive B-scans were obtained in the same visit. After multiple B-scan averaging, the respective global and sectoral (superonasal, nasal, inferonasal, inferotemporal, temporal, and superotemporal) RNFL thicknesses were compared with linear mixed modeling and analyzed for RNFL measurement variability. RESULTS: There was no RNFL segmentation failure in all the scans. No significant differences were found in global or sectoral RNFL thicknesses among the image series averaged with different number of B-scan except for the inferonasal sector in the glaucoma group (P=0.036). The intraclass correlation coefficients were all >0.971 and the coefficients of variation were all below 4.33% for both sectoral and global RNFL thicknesses. No significant differences in the image quality score were detected among the image series (P≥0.141). CONCLUSIONS: Although multiple B-scan averaging is commonly applied to enhance visualization of the retinal layers in OCT images, it may not have a significant impact on global and sectoral RNFL thicknesses measured by the Spectralis OCT.
机译:目的:确定多次B扫描平均对使用光谱域光学相干断层扫描仪(OCT)进行的视网膜神经纤维层(RNFL)厚度测量的影响。方法:检查25例正常人和29例青光眼患者。通过Spectralis OCT(Heidelberg Engineering,Heidelberg,GmbH,Dossenheim,Germany)从每个参与者中随机选择一只眼睛进行环乳头RNFL扫描。在同一次访问中获得了三组包括2、8和16个连续B扫描的OCT图像系列。在多次B扫描平均后,将各个整体和扇形(鼻上,鼻,鼻下,颞下,颞和颞上)的RNFL厚度与线性混合模型进行比较,并分析RNFL测量的可变性。结果:在所有扫描中均没有RNFL分割失败。除青光眼组的鼻下扇形外(B = 0.036),在不同数量的B超检查的平均图像系列中,在整体或扇形的RNFL厚度上没有发现显着差异。对于扇形和整体RNFL厚度,组内相关系数均> 0.971,变异系数均低于4.33%。在各图像系列之间未检测到图像质量得分的显着差异(P≥0.141)。结论:尽管通常采用多次B扫描平均来增强OCT图像中视网膜层的可视化,但它可能不会对Spectralis OCT测量的整体和扇形RNFL厚度产生重大影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号