PURPOSE: To determine the within-trial and between-trial repeatability of pattern electroretinogram (PERG) measurements in healthy and patient eyes, using a new clinical instrument, the PERGLA. STUDY DESIGN: In all, 70 eyes of 35 healthy individuals (intraocular pressure <22 mm Hg, healthy optic disc by stereophotograph assessment, standard visual fields within normal limits) and 90 eyes of 45 clinic patients (ocular hypertensive, glaucomatous optic neuropathy by stereophotograph assessment and/or repeatable abnormal visual fields) enrolled in the University of California, San Diego Diagnostic Innovations in Glaucoma Study (DIGS) were evaluated. Average mean deviation of patient eyes on standard automated perimetry was -1.81 dB (SD=2.61). METHODS: The PERG was recorded using the PERGLA paradigm from both eyes simultaneously twice (ie, 2 trials) by a single operator with electrodes being removed and reattached between recordings. Repeatability of PERG amplitude (microV) and phase (pi rad) between 2 runs within a single trial (within-trial condition) was compared with repeatability between 2 trials (ie, after electrode replacement, between-trial condition) by calculating the coefficients of variability (CVs) and the intraclass correlation coefficients (ICCs) and displaying Bland-Altman plots. RESULTS: For healthy eyes, amplitude CVs (SD) were 11.5% (11.5) and 9.9% (0.79) for within-trial and between-trial conditions, respectively. ICCs were 0.91 and 0.85. Phase CVs were 1.3% (1.5) (within-trials) and 1.5% (1.4) (between-trials) and ICCs were 0.85 and 0.88. For patient eyes, amplitude CVs (SD) were 12.2% (10.1) and 11.2% (7.5) for within-trial and between-trial conditions, respectively. ICCs were 0.92 and 0.89. Phase CVs were 2.2% (2.2) (within-trials) and 2.4% (2.2) (between-trials) and ICCs were 0.82 and 0.83. Bland-Altman plots indicated good agreement between the repeated recordings and were similar within-trials and between-trials for healthy and patient eyes. CONCLUSIONS: Repeatability of PERGLA recordings is good and is similar within-trials and between-trials for both healthy and patient eyes suggesting this technique is promising for monitoring change over time.
机译:目的:使用一种新型的临床仪器PERGLA,确定健康和患者眼睛中的视网膜电图(PERG)测量值的试验内和试验间重复性。研究设计:总共35例健康个体的70眼(眼压<22 mm Hg,通过立体照片评估为健康的视盘,正常视野内的正常视野)和45例临床患者的90眼(通过立体照片进行眼压性高血压,青光眼性视神经病变加州大学圣地亚哥分校青光眼诊断创新研究(DIGS)中评估的评估和/或可重复的异常视野进行了评估。在标准自动视野检查中,患者眼睛的平均平均偏差为-1.81 dB(SD = 2.61)。方法:使用PERGLA范例,由一位操作者从两只眼睛同时两次记录PERG(即2次试验),并取下电极并在记录之间重新连接。通过计算下式的系数,将一次试验(两次试验)内两次运行之间的PERG振幅(微伏)和相位(πrad)的重复性与两次试验之间(即电极更换后,两次试验之间)的重复性进行比较。变异性(CV)和类内相关系数(ICC)并显示Bland-Altman图。结果:对于健康的眼睛,试验内和试验间情况的振幅CV(SD)分别为11.5%(11.5)和9.9%(0.79)。 ICC为0.91和0.85。阶段CV为1.3%(1.5)(试验内)和1.5%(1.4)(试验间),ICC为0.85和0.88。对于患者的眼睛,在试验内和试验间情况下,振幅CV(SD)分别为12.2%(10.1)和11.2%(7.5)。 ICC分别为0.92和0.89。阶段CV为2.2%(2.2)(试验内)和2.4%(2.2)(试验间),ICC为0.82和0.83。 Bland-Altman图表明重复记录之间有很好的一致性,对于健康和患者的眼睛来说,在试验内和试验间相似。结论:PERGLA记录的可重复性良好,对于健康和患者的眼睛而言,在试验内和试验间均相似,这表明该技术有望监测随时间的变化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号