首页> 外文期刊>Journal of forensic sciences. >Improper sealing caused by the Styrofoam integrity seals in leakproof plastic bottles lead to significant loss of ethanol in frozen evidentiary urine samples.
【24h】

Improper sealing caused by the Styrofoam integrity seals in leakproof plastic bottles lead to significant loss of ethanol in frozen evidentiary urine samples.

机译:防漏塑料瓶中的聚苯乙烯泡沫塑料完整性密封造成的密封不当会导致冷冻证据尿液样本中的乙醇大量流失。

获取原文
获取原文并翻译 | 示例
       

摘要

Evidentiary urine samples (n = 345) stored frozen at -20 degrees C in their original containers (leakproof 100 mL plastic bottles) upon retesting for ethanol resulted in concentrations that were significantly lower (average loss = approximately 30%) than those prior to their storage at -20 degrees C (p < or = 0.0001). The observed loss of ethanol was independent of the method of thawing or the concentration of ethanol in the samples, but was dependent on the sample volume in the container, i.e., the larger the volume of sample the larger the magnitude of ethanol loss. The loss of ethanol was determined to be due to improper sealing by a Styrofoam integrity seal attached to the mouth of the container. Accordingly, adopting leakproof plastic containers that do not contain Styrofoam integrity seals, but rather an outside and across the cap tape integrity seal for evidence collection and long-term storage, will prevent loss of ethanol due to evaporation.
机译:重新测试乙醇后,证据尿液样本(n = 345)在-20摄氏度下冷冻保存在其原始容器(防漏100 mL塑料瓶)中,所产生的浓度明显低于其之前的浓度(平均损失=约30%)。储存在-20摄氏度(p <或= 0.0001)。观察到的乙醇损失与解冻方法或样品中乙醇的浓度无关,但取决于容器中样品的体积,即,样品体积越大,乙醇损失的幅度越大。确定乙醇损失是由于附着在容器口上的聚苯乙烯泡沫塑料完整性密封件密封不当所致。因此,采用不包含聚苯乙烯泡沫塑料完整性密封件,而是外部和整个帽带完整性密封件以供取证和长期保存的防漏塑料容器将防止乙醇因蒸发而损失。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号