摘要

Cu(II)eocuproine (2,9-dimethyl-1,10-phenanthroline) complexes were utilized for spectrophotometric determination of total polyphenol content in beers. This procedure is based on the reduction of Cu(II) by polyphenols in hydroethanolic medium (pH 7.0) in the presence of neocuproine, yielding Cu(I)/complexes with maximum absorption at 454 nm. The sensitivity of the proposed method was compared with the AOAC method using tannic and gallic acid as standards. The average apparent molar absorptivity, in L cm--1 mol--1, of tannic acid (3.50 +or- 0.20) x 105 and gallic acid (5.12 +or- 0.21) x 104, was twice as high for the proposed method. A lower limit of detection (LOD) (2.9 x 10--1 mg L--1) was found when tannic acid was used in the proposed method. Additionally, less interference from the most common additives in beers was noticed. Total content of polyphenols was analyzed in 17 Brazilian samples. Results ranged from 35.5 to 556 mg L--1 of tannic acid, with higher values for recovery rates (45.4-118%, mean 85.0%) than for gallic acid. Although tannic acid is a mixture of polygalloyl glucoses, the total polyphenol content found in the samples suggests that tannic acid should be used as a standard. This is the first attempt to use this particular copper complex to quantify total polyphenol content in beer samples
机译:铜(II)/新铜(2,9-二甲基-1,10-菲咯啉)配合物用于分光光度法测定啤酒中的总多酚含量。此步骤基于在新铜环素存在下,氢乙醇介质(pH 7.0)中多酚对Cu(II)的还原作用,从而生成Cu(I)/络合物,在454 nm处具有最大吸收。将该方法的灵敏度与以鞣酸和没食子酸为标准品的AOAC方法进行了比较。单宁酸(3.50 +或-0.20)x 10 5 mol -1 >和没食子酸(5.12 +或-0.21)x 10 4 ,是该方法的两倍。当使用单宁酸时,发现最低检出限(LOD)为2.9 x 10 -1 mg L -1 。另外,注意到啤酒中最常见添加剂的干扰较小。在巴西的17个样品中分析了多酚的总含量。结果范围为35.5至556 mg L -1 的单宁酸,其回收率比没食子酸高(45.4-118%,平均85.0%)。尽管单宁酸是聚没食子酰基葡萄糖的混合物,但样品中的总多酚含量表明单宁酸应用作标准品。这是首次尝试使用这种特殊的铜络合物定量啤酒样品中的总多酚含量

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号