Comparison of high-definition oscillometry - a non-invasive technology for arterial blood pressure measurement - with a direct invasive method using radio-telemetry in awake healthy cats.

机译:高清晰度示波法(一种用于动脉血压测量的非侵入性技术)与使用无线电遥测法的直接侵入性方法在清醒的健康猫中的比较。

获取原文
获取原文并翻译 | 示例
       

摘要

This study compared indirect blood pressure measurements using a non-invasive method, high-definition oscillometry (HDO), with direct measurements using a radio-telemetry device in awake cats. Paired measurements partitioned to five sub-ranges were collected in six cats using both methods. The results were analysed for assessment of correlation and agreement between the two methods, taking into account all pressure ranges, and with data separated in three sub-groups, low, normal and high ranges of systolic (SBP) and diastolic (DBP) blood pressure. SBP data displayed a mean correlation coefficient of 0.92+or-0.02 that was reduced for low SBP. The agreement level evaluated from the whole data set was high and slightly reduced for low SBP values. The mean correlation coefficient of DBP was lower than for SBP (ie, 0.81+or-0.02). The bias for DBP between the two methods was 22.3+or-1.6 mmHg, suggesting that HDO produced lower values than telemetry. These results suggest that HDO met the validation criteria defined by the American College of Veterinary Internal Medicine consensus panel and provided a faithful measurement of SBP in conscious cats. For DBP, results suggest that HDO tended to underestimate DBP. This finding is clearly inconsistent with the good agreement reported in dogs, but is similar to outcomes achieved in marmosets and cynomolgus monkeys, suggesting that this is not related to HDO but is species related. The data support that the HDO is the first and only validated non-invasive blood pressure device and, as such, it is the only non-invasive reference technique that should be used in future validation studies.Digital Object Identifier http://dx.doi.org/10.1177/1098612X13495025
机译:这项研究比较了使用无创方法,高清示波法(HDO)进行的间接血压测量与使用无线电遥测设备对清醒的猫进行的直接血压测量。使用这两种方法,在六只猫中收集了划分为五个子范围的配对测量值。分析结果以评估两种方法之间的相关性和一致性,同时考虑所有压力范围,并将数据分为三个子组,分别为收缩压(SBP)和舒张压(DBP)的低,正常和高范围。 SBP数据显示平均相关系数为0.92+或-0.02,对于低SBP而言,该系数降低了。从整个数据集评估的一致性水平很高,而对于较低的SBP值则略有降低。 DBP的平均相关系数低于SBP(即0.81+或-0.02)。两种方法之间DBP的偏差为22.3±1.6 mmHg,这表明HDO产生的值低于遥测。这些结果表明,HDO符合美国兽医内部医学学院共识小组定义的验证标准,并为有意识的猫提供了对SBP的忠实测量。对于DBP,结果表明HDO倾向于低估DBP。这一发现显然与狗中报道的良好一致性不一致,但与and猴和食蟹猴所获得的结果相似,表明这与HDO无关,但与物种有关。数据支持HDO是第一个也是唯一一个经过验证的非侵入性血压设备,因此,它是将来验证研究中应使用的唯一非侵入性参考技术。数字对象标识符http://dx.com。 doi.org/10.1177/1098612X13495025

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号