首页> 外文期刊>Journal of Failure Analysis and Prevention >Weld Failure Analysis of Air Radiator
【24h】

Weld Failure Analysis of Air Radiator

机译:空气散热器的焊接失效分析

获取原文
获取原文并翻译 | 示例

摘要

The air radiator had been in service for more than 30 years until a notch failure occurred. In this paper, a rare notch failure is completely investigated by means of macroscopic and microscopic observations, microstructural inspection, chemical analysis, and residual stress test. The results show that the notch failure mode of the air radiator is attributed to high-cycle fatigue fracture, due to the welded lapping surfaces near the notch on both sides of the corrugated plate trough not being put onto one plane during the welding process. Therefore, in order to prevent or reduce possible tensile stress, it is recommended that the welded lapping surfaces be put onto one plane before welding.
机译:直到出现缺口故障,空气散热器已经使用了30多年。本文通过宏观和微观观察,微观结构检查,化学分析和残余应力测试对罕见的缺口破坏进行了全面研究。结果表明,由于在焊接过程中瓦楞板槽两侧的缺口附近的焊接搭接面未放置在一个平面上,因此空气散热器的缺口失效模式归因于高周疲劳断裂。因此,为了防止或减小可能的拉应力,建议在焊接前将焊接的研磨表面放在一个平面上。