Cracking was found on the welded elbow at the bottom of rectifying tower in an alcohol evaporation system. In order to determine the cause of failure, a detailed analysis was conducted. The analysis included macroscopic observation for the failed tube and optical microscopy for the morphology of cracks. The characterization of fracture was analyzed by scanning electron microscopy, and the components subjected to the cracks were analyzed using energy-dispersive x-ray spectroscopy. Results revealed that the welded elbow had suffered damage from external chloride stress corrosion cracking (EC-SCC). The environmental factor responsible for ECSCC is the chloride present in the dampish insulation. The stress factor is the result of the welding residual stress induced in the material which was used to fabricate the elbow.
机译:在酒精蒸发系统中,精馏塔底部的焊接弯头出现裂纹。为了确定故障原因,进行了详细的分析。分析包括对失效管的宏观观察和对裂纹形态的光学显微镜观察。通过扫描电子显微镜分析断裂的特征,并使用能量色散X射线光谱法分析经受裂纹的部件。结果显示,焊接肘部受到外部氯化物应力腐蚀开裂(EC-SCC)的破坏。造成ECSCC的环境因素是潮湿绝缘中存在的氯化物。应力因子是在用于制造弯头的材料中产生的焊接残余应力的结果。