Failure Analysis of T12 Boiler Re-Heater Tubes During Short-Term Service

机译:T12锅炉再热器短期维修中的失效分析

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The failure of T12 re-heater tubes that had been in service only for 3000 h was investigated. The wall thickness of the tubes was visibly reduced by heavy oxidation corrosion on the outer and inner walls. The original pearlite substrate completely decomposed. Uniform oxide scale appearance on the inner wall shows obvious vapor oxidation corrosion characteristics. Corrosion originated in the grain boundary, and selective oxidation occurred due to ion diffusion in the substrate. The layered oxide scale formed on the inner wall is related to the different diffusion rates for different cations. Exposure to high temperature corrosive flux accelerated the corrosion on the outer wall. The microstructure degradation and corrosion characteristics of the tubes indicate that the tubes failed primarily because of overheating, as evidenced by calculations.
机译:研究了仅使用了3000小时的T12再热器管的故障。通过在外壁和内壁上的严重氧化腐蚀明显减小了管的壁厚。原始的珠光体基质完全分解。内壁上均匀的氧化皮外观显示出明显的蒸气氧化腐蚀特征。腐蚀起源于晶界,并且由于离子在基板中的扩散而发生选择性氧化。在内壁上形成的层状氧化皮与不同阳离子的不同扩散速率有关。暴露于高温腐蚀剂会加速外壁的腐蚀。管的微观结构退化和腐蚀特性表明,管的失效主要是由于过热,如计算所示。