...
首页> 外文期刊>Journal of environmental monitoring: JEM >Analysis of HO-PCBs and PCP in blood plasma from individuals with high PCB exposure living on the Chukotka Peninsula in the Russian Arctic
【24h】

Analysis of HO-PCBs and PCP in blood plasma from individuals with high PCB exposure living on the Chukotka Peninsula in the Russian Arctic

机译:居住在俄罗斯北极楚科奇半岛的高PCB暴露人群血浆中HO-PCBs和PCP的分析

获取原文
获取原文并翻译 | 示例
           

摘要

A trace analytical method is presented for the analysis of hydroxylated polychlorinated biphenyl metabolites (HO-PCBs) and pentachlorophenol (PCP) in human plasma.The described methodology is a modification of a previously validated method used for PCB and organochlorine pesticide analysis.The modified method enables the combined analysis of phenolic and neutral halogenated compounds.A tandem Florisil column is used for separating the HO-PCBs and PCP from the neutral fraction,instead of the more common chemical partitioning.In the same step the neutral fraction is purified for GC analysis.The extraction of the HO-PCBs and PCP was found to be highly dependent on sufficient acidification of the sample and the polarity of the extracting solvent.Analysis of plasma samples gave recovery rates for ~(13)C_6-PCP and ~(13)C_(12)-4-HO-CB 187 of 64 and 72%,respectively.The limit of detection ranged between 2-20 pg g~(-1) plasma for the HO-PCBs and 5 pg g~(-1) plasma for PCP.No matrix interferences were observed in the chromatograms.In plasma samples (n = 15) from the native Chukchi people in Uelen (Russian Arctic),a population with high PCB exposure,the median ratio of sum HO-PCBs to sum PCBs was as high as 0.4 and the sum HO-PCBs and PCBs were significantly correlated (r~2 > 0.7,p < 0.01).The median sum HO-PCBs (10 congeners) was 5920 pg g~(-1) plasma with 4-HO-CB 107 as the dominating congener (median:1670 pg g~(-1) plasma).The median PCP level was measured at 642 pg g~(-1) plasma.
机译:提出了一种痕量分析方法,用于分析人血浆中的羟基化多氯联苯代谢物(HO-PCBs)和五氯苯酚(PCP),该方法是对先前已验证的PCB和有机氯农药分析方法的改进。实现串联分析酚醛和中性卤化物发现HO-PCBs和PCP的提取高度依赖于样品的充分酸化和萃取溶剂的极性。血浆样品的分析得出〜(13)C_6-PCP和〜(13)的回收率C_(12)-4-HO-CB 187分别为64%和72%.HO-PCB的检测限介于2-20 pg g〜(-1)血浆和5 pg g〜(-1)之间PCP等离子体,无基质干扰在色谱图中观察到了s。在来自Uelen(俄罗斯北极)的楚克奇人的血浆样本(n = 15)中,PCB暴露量很高,HO-PCB和PCB总数之和的中值比高达0.4。并且HO-PCBs和PCBs的总含量显着相关(r〜2> 0.7,p <0.01)。血浆中HO-PCBs(10个同类物)的中位数为5920 pg g〜(-1)血浆和4-HO-CB 107作为主要同类物(中位数:1670 pg g〜(-1)血浆).PCP中值测量为642 pg g〜(-1)血浆。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号