首页> 外文期刊>Journal of Endodontics: Official Journal of American Association of Endodontists >Measurement of endodontic file lengths: a density profile plot analysis.
【24h】

Measurement of endodontic file lengths: a density profile plot analysis.

机译:牙髓锉长度的测量:密度分布图分析。

获取原文
获取原文并翻译 | 示例
           

摘要

The purpose of this study was to evaluate measurements of endodontic files of known length and diameter using a density profile plot analysis of digital images. Ten single-rooted teeth with relatively straight roots in cadaver specimens were used. The crowns of the teeth were removed and a rectangular orthodontic wire, 5.13 mm in length, was placed horizontally on the occlusal surface to serve as a calibration reference point. The #8, #10, #15, and #20 FlexOFiles were measured to the nearest 0.5 mm and then placed to four working lengths that terminated within the apical third of each root. A GE X-ray unit and a Schick CDR #2 sensor were used to digitally acquire 160 images. The digital images were placed in random order and an independent, blinded investigator determined the file length using a density profile plot analysis. The measurements generated by the histogram analysis (experimental) were compared with the original clinical measurements. The paired t test, intraclass correlation coefficient, and the Bradley-Blackwood test were used to assess reliability. The results revealed that the means of the experimental measurements of all file sizes were within 0.5 mm of the known lengths and were always shorter than the known lengths. Also, the larger the file size the less deviation from the known lengths: #20, -0.16 mm (p = 0.0001); #15, -0.21 mm (p = 0.0001); #10, -0.34 mm (p = 0.0001); and #8, -0.45 mm (p = 0.0001). This study demonstrated that the density profile plot analysis might be a useful adjunct for the measurement of endodontic file lengths on a digital image.
机译:这项研究的目的是使用数字图像的密度分布图分析评估已知长度和直径的牙髓锉的测量结果。在尸体标本中使用了十根根相对较直的单根牙齿。去除牙齿的牙冠,将长5.13毫米的矩形正畸钢丝水平放置在咬合面上,作为校准参考点。测量#8,#10,#15和#20 FlexOFiles到最接近的0.5毫米,然后放置到四个工作长度,该长度终止于每个根的顶端三分之一内。 GE X射线装置和Schick CDR#2传感器用于数字采集160张图像。数字图像以随机顺序放置,独立的盲人调查员使用密度分布图分析确定文件长度。将直方图分析生成的测量值(实验性)与原始临床测量值进行比较。配对t检验,组内相关系数和Bradley-Blackwood检验用于评估可靠性。结果表明,所有文件尺寸的实验测量方法均在已知长度的0.5毫米以内,并且总是短于已知长度。同样,文件大小越大,与已知长度的偏差就越小:#20,-0.16 mm(p = 0.0001); #15,-0.21毫米(p = 0.0001); #10,-0.34毫米(p = 0.0001); #8,-0.45毫米(p = 0.0001)。这项研究表明,密度分布图分析可能是测量数字图像上牙髓锉长度的有用辅助工具。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号