INTRODUCTION: This study compared the torsional resistance of two brands of rotary nickel-titanium (NiTi) instruments indicated for endodontic retreatment. METHODS: Mtwo retreatment instruments #15 and #25 (VDW, Munich, Germany) and ProTaper Universal retreatment instruments D2 and D3 (Maillefer/Dentsply, Ballaigues, Switzerland) were subjected to a torsional assay in clockwise rotation. The two parameters evaluated were maximum torque and angular deflection at failure. Fractured instruments had their fractured surfaces and helical shafts examined by scanning electron microscopy. RESULTS: The results indicated that the angular deflection at fracture decreased in the following order: Mtwo retreatment file #15 > Mtwo retreatment file #25 > ProTaper Universal retreatment file D2 > ProTaper Universal retreatment file D3. As for the maximum torque values, the results revealed the following descending order: ProTaper Universal file D2 > Mtwo retreatment file #25 > ProTaper Universal file D3 > Mtwo retreatment file #15. Scanning electron microscopic analysis revealed that plastic deformation occurred along the helical shaft of the fractured instruments. Fractured surfaces were of the ductile type. CONCLUSIONS: The instruments tested showed different torsional behavior depending on the parameter evaluated. If one considers that high angular deflection values may serve as a safety factor, then the Mtwo retreatment instruments showed significantly better results.
机译:简介:这项研究比较了两种用于牙髓治疗的品牌旋转镍钛(NiTi)器械的抗扭强度。方法:对Mtwo重复治疗仪器#15和#25(VDW,慕尼黑,德国)和ProTaper Universal重复治疗仪器D2和D3(Maillefer / Dentsply,瑞士Ballaigues)进行了顺时针旋转的扭转测定。评估的两个参数是最大扭矩和失效时的角偏转。断裂的器械的断裂表面和螺旋轴通过扫描电子显微镜检查。结果:结果表明,骨折时的角偏转按以下顺序减小:Mtwo修复锉刀#15> Mtwo修复锉刀#25> ProTaper Universal修复锉刀D2> ProTaper Universal修复锉刀D3。至于最大扭矩值,结果显示按以下降序排列:ProTaper Universal文件D2> Mtwo重新处理文件#25> ProTaper Universal文件D3> Mtwo重新处理文件#15。扫描电子显微镜分析表明,塑性变形沿破裂器械的螺旋轴发生。断裂表面是韧性类型的。结论:根据所评估的参数,所测试的器械表现出不同的扭转性能。如果人们认为高角度偏转值可以作为一种安全因素,那么Mtwo的再治疗仪器将显示出明显更好的结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号