Durability and validity of a remote, miniaturized pressure sensor in an animal model of abdominal aortic aneurysm.

机译:远程小型压力传感器在腹主动脉瘤动物模型中的耐用性和有效性。

获取原文
获取原文并翻译 | 示例
       

摘要

Purpose: To investigate whether a remote, miniaturized pressure sensor could maintain calibration and function through organized thrombus over an extended period in a porcine model of abdominal aortic aneurysm (AAA).Methods: Six adult pigs had an AAA surgically created and excluded. A sensor zeroed to atmospheric pressure was placed within the aneurysm sac and another within the suprarenal aorta of each animal. Pressure measurements were taken at the initial operation and then on a weekly basis over 2 months. The aortic sensors were correlated to an intra-arterial pressure catheter at the initial operation and at the time of sacrifice. Back-table sensor correlation with atmospheric pressure was done at the time of explantation.Results: Three animals died during the follow-up period. Five animals were available for 6-week follow-up, of which 3 survived for the complete 8-week protocol. Two of the surviving animals had an intra-aortic sensor. All 5 aneurysm sac sensors functioned throughout the experimental period. At the time of sacrifice, the sacs contained a large amount of organized thrombus in which the sac sensors were deeply embedded. The 3 aortic sensors also functioned throughout the course of the experiments. The pressures correlated within 5 mmHg to the catheter-based measurements taken at the initial operation and at the time of sacrifice. Comparison to atmospheric pressure revealed no calibration offset in any sensor.Conclusions: This chronic implantation study demonstrates the durability of a remote, miniaturized pressure sensor within a surgically created aneurysm sac as well as the suprarenal aorta of a porcine AAA model. There was no calibration offset in any of the sensors, and they remained valid at explantation. We believe that this is further evidence of the potential applicability of this sensor for clinical use.
机译:目的:探讨远程小型压力传感器是否可以在猪腹主动脉瘤(AAA)模型中通过有组织的血栓长时间维持校准和功能。方法:六只成年猪通过手术创建并排除了AAA。将调零至大气压的传感器放置在每只动物的动脉瘤囊内,另一个放置在肾上主动脉内。在初始操作时进行压力测量,然后在2个月内每周一次。在初次手术时和处死时,主动脉传感器与动脉内压力导管相关。移出时进行了台面传感器与大气压力的相关性。结果:在随访期间三只动物死亡。五只动物可用于6周的随访,其中3只在完整的8周方案中存活。幸存的两只动物具有主动脉内传感器。在整个实验期间,所有5个动脉瘤囊型传感器均正常工作。在牺牲时,囊中包含大量有组织的血栓,囊传感器深深地嵌入其中。在整个实验过程中,这3个主动脉传感器也都起作用。压力在5 mmHg之内与在初始操作和处死时进行的基于导管的测量值相关。与大气压力的比较显示任何传感器都没有校准偏差。结论:这项长期的植入研究表明,在外科手术创建的动脉瘤囊以及猪AAA模型的肾上主动脉中,远程小型压力传感器的耐用性。任何传感器都没有校准偏差,并且在移栽时它们仍然有效。我们相信,这进一步证明了该传感器在临床上的潜在适用性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号