A laboratory electrostatic precipitator (ESP) with electrode shapes and spacing of commercial design has been energised with a pulsed power supply of high flexibility. The resulting current and charge has been measured as a function of time with fast monitors. It could be verified experimentally that the corona current prevails much longer than the length of a high-voltage pulse, since the motion of ions is much slower than high-voltage switching. Variations of pulse length between 10 mu s and 1 ms resulted only in moderate changes of the average corona current, as a result of corona self-quenching. In accordance with these observations, a very high initial pulse current was followed by an order of magnitude lower equilibrium current in a longer pulse. The initial current was strongly influenced by pulse rise time. A back corona situation was generated by high resistivity fly ash on the plates and the selection of high pulse repetition rates. It could be shown that the onset of back corona is delayed to the high-voltage pulse by the ion drift time. (C) 2000 Elsevier Science B.V. All rights reserved. [References: 13]
机译:具有电极形状和商业设计间距的实验室静电除尘器(ESP)已通过高灵活性的脉冲电源供电。快速监视器已测量出作为结果的电流和电荷。可以通过实验证明,电晕电流的存在时间比高压脉冲的时间长得多,因为离子的运动比高压开关的运动慢得多。由于电晕自猝灭,脉冲长度在10毫秒和1毫秒之间的变化仅导致平均电晕电流的适度变化。根据这些观察,在较长的脉冲中,非常高的初始脉冲电流之后是一个较低数量级的平衡电流。初始电流受到脉冲上升时间的强烈影响。板上的高电阻率粉煤灰和高脉冲重复频率的选择产生了反向电晕情况。可以证明,由于离子漂移时间,反电晕的发生被延迟到高压脉冲。 (C)2000 Elsevier Science B.V.保留所有权利。 [参考:13]

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号