Introduction Detection of QRS complexes, P-waves and atrial fibrillation f-waves in electrocardiographic (ECG) signals is critical for the correct diagnosis of arrhythmias. We aimed to find the best bipolar lead (BL) with the highest signal amplitude and shortest inter-electrode spacing. Methods ECG signals (120 seconds) were recorded in 36 patients with 16 precordial electrodes placed in a standardized pattern. An average signal was analysed for each of 120 possible BLs obtained by calculating the difference between pairs of unipolar leads. Peak-to-peak amplitudes of QRS waves (50 ms around R-peak) and P waves (270-70 ms before R-peak) were calculated. For patients with atrial fibrillation, power of the fibrillatory (f) wave was used instead. Maximum values at each distance were considered and differentiation analysis was performed based on incremental changes (amplitude to distance). Results There was a significant correlation between distance and QRS-amplitude (r = 0.78, p 0.001), P-wave amplitude (r = 0.60, p 0.01) and f-wave power (r = 0.79, p 0.001). The range of values was: QRS-amplitude 0.7-2.33 mV, P-wave amplitude 0.07-0.18 mV, and f-wave power 0.55-2.12 mV2/s. The maximum value for the shortest distance was on a heart-aligned axis over the left ventricle for the QRS complex (1.9 mV at 8.7 cm) and over the atria for the P-wave (0.98 mV) and f-waves (1.45 mV2/s at 8 cm, respectively). Conclusion There is a strong positive correlation between electrode distance and ECG signal-amplitude. Distance of 8 cm on a heart-aligned axis and over the relevant heart-chamber provides the highest signal amplitude for the shortest distance. These findings are essential for the design and use of ambulatory monitoring devices.
机译:简介检测心电图(ECG)信号中的QRS复合波,P波和房颤f波对于正确诊断心律不齐至关重要。我们旨在找到具有最高信号幅度和最短电极间距的最佳双极引线(BL)。方法在36例患者中记录心电图信号(120秒),并以标准化方式放置16个心前电极。通过计算成对的单极引线之间的差异,对120种可能的BL中的每一个进行了平均信号分析。计算了QRS波(R峰周围50 ms)和P波(R峰之前270-70 ms)的峰峰幅度。对于患有房颤的患者,可使用颤动(f)波的功率代替。考虑每个距离的最大值,并根据增量变化(幅度到距离)进行差异分析。结果距离与QRS振幅(r = 0.78,p <0.001),P波振幅(r = 0.60,p <0.01)和f波功率(r = 0.79,p <0.001)之间存在显着相关性。值的范围为:QRS振幅0.7-2.33 mV,P波振幅0.07-0.18 mV和f波功率0.55-2.12 mV2 / s。最短距离的最大值是QRS复合波在左心室上方的心轴上(8.7 cm时为1.9 mV),P波(0.98 mV)和f波(1.45 mV2 /分别在8厘米处)。结论电极距离与心电信号幅度之间存在很强的正相关关系。心脏对齐轴上和相关心脏腔上的8 cm距离可在最短距离内提供最高信号幅度。这些发现对于动态监视设备的设计和使用至关重要。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号