This study sought to determine the efficiency of various ultrafiltration cartridges (UFC) in concentrating test microorganisms from drinking water. Replicate drinking water samples from 3 potable water supplies were dosed with Bacillus anthracis, Francisella tularensis LVS, Yersinia pestis CO92, bacteriophages MS2 and phi-X174, and Cryptosporidium parvum. The test microorganisms were dosed together in 100 l of water, which was then recirculated through 1 of 5 different UFC until the retentate vol. was reduced to approx. 500 ml. The microorganisms were assayed before and after ultrafiltration concentration and percentage recoveries were calculated. There were 9 statistically significant differences among pairs of filters out of a possible 180 different combinations of UFC, test microorganisms, and water types. No filter consistently performed better or worse than the others for each test microorganism in all water samples tested. It is suggested that water utilities and 1st responders may use these data when selecting UFC for use in emergency response protocols.
机译:这项研究试图确定各种超滤滤芯(UFC)从饮用水中浓缩测试微生物的效率。对来自3个饮用水的重复饮用水样品中的炭疽芽孢杆菌,土拉弗朗西斯菌LVS,鼠疫耶尔森菌CO92,噬菌体MS2和phi-X174和小隐孢子虫进行了剂量测定。将受试微生物一起加入100升水中,然后通过5种不同的UFC中的1种进行再循环,直至截留液体积增加。减少到大约500毫升在超滤浓度之前和之后测定微生物,并计算回收率。在UFC,测试微生物和水类型的可能的180种不同组合中,过滤器对之间存在9个统计上的显着差异。对于所有测试水样中的每种测试微生物,没有一种过滤器的性能始终优于或劣于其他过滤器。建议水务公司和第一响应者在选择用于应急响应协议的UFC时可以使用这些数据。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号