首页> 外文期刊>Clinical chemistry and laboratory medicine: CCLM >Toward standardization of carbohydrate-deficient transferrin (CDT) measurements: II. Performance of a laboratory network running the HPLC candidate reference measurement procedure and evaluation of a candidate reference material.
【24h】

Toward standardization of carbohydrate-deficient transferrin (CDT) measurements: II. Performance of a laboratory network running the HPLC candidate reference measurement procedure and evaluation of a candidate reference material.

机译:迈向缺乏碳水化合物的转铁蛋白(CDT)测量标准化:II。运行HPLC候选参照物测量程序并评估候选参照物的实验室网络的性能。

获取原文
获取原文并翻译 | 示例
       

摘要

Carbohydrate-deficient transferrin (CDT) is a descriptive term used for a temporary change in the transferrin glycosylation profile caused by alcohol, and used as a biomarker of chronic high alcohol consumption. The use of an array of methods for measurement of CDT in various absolute or relative amounts, and sometimes covering different transferrin glycoforms, has complicated the comparability of results and caused confusion among medical staff. This situation prompted initiation of an IFCC Working Group on CDT standardization. This second publication of the WG-CDT covers the establishment of a network of reference laboratories running a high-performance liquid chromatography (HPLC) candidate reference measurement procedure, and evaluation of candidate secondary reference materials. The network laboratories demonstrated good and reproducible performance and thus can be used to assign target values for calibrators and controls. A candidate secondary reference material based on native human serum lyophilized with a cryo-/lyoprotectant to prevent protein denaturation was found to be commutable and stable during storage. A proposed strategy for calibration of different CDT methods is also presented. In an external quality assurance study involving 66 laboratories and covering the current routine CDT assays (HPLC, capillary electrophoresis and immunoassay), recalculation of observed results based on the nominal values for the candidate calibrator reduced the overall coefficient of variation from 18.9% to 5.5%. The logistics for distribution of reference materials and review of results were found to be functional, indicating that a full reference system for CDT may soon be available.
机译:碳水化合物不足的转铁蛋白(CDT)是一个描述性术语,用于暂时改变由酒精引起的转铁蛋白糖基化分布,并用作长期大量饮酒的生物标记。使用一系列测量各种绝对或相对量的CDT的方法,有时包括不同的转铁蛋白糖型,已经使结果的可比性复杂化,并引起医务人员的困惑。这种情况促使成立了IFCC CDT标准化工作组。 WG-CDT的第二本出版物涵盖建立参考实验室网络的过程,该网络运行高性能液相色谱(HPLC)候选参考测量程序,并对候选辅助参考材料进行评估。网络实验室表现出良好且可重复的性能,因此可用于为校准器和控件分配目标值。已发现基于冷冻或冻干保护剂冻干以防止蛋白质变性的天然人血清的候选二级参考物质在储存过程中可交换和稳定。还提出了用于校准不同CDT方法的建议策略。在一项涉及66个实验室并涵盖当前常规CDT分析(HPLC,毛细管电泳和免疫分析)的外部质量保证研究中,基于候选校准物的标称值对观察结果进行的重新计算将总变异系数从18.9%降低至5.5% 。发现分发参考材料和审查结果的后勤功能正常,这表明CDT的完整参考系统可能很快可用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号