A sensitive reversed-phase high-performance liquid chromatographic (RP-HPLC) assay with on-line extraction was developed for quantifying ertapenem in human cerebrospinal fluid (CSF). This assay is at least five times more sensitive than previously published ertapenem methods with a lower limit of quantitation at 0.025 g/ml. In this assay, a CSF sample is extracted on-line using a RP extraction column and an aqueous acidic mobile phase (0.1% formic acid) to wash away polar endogenous materials, while ertapenem is retained on the column. Ertapenem is then back-flushed off the extraction column and directed to a RP analytical column using an acidic mobile phase with an organic modifier (acetonitrile/0.1% formic acid, 15:85 (v/v)) and detected using UV absorbance. The acidic mobile phase provided a sharper chromatographic peak and on-line extraction allowed large injection volumes (≥150 μl) of buffered CSF to be injected without compromising column integrity. These assay conditions were necessary to quantify ertapenem at levels expected to be found in human CSF (<0.05 μg/ml). The method was successfully validated and implemented for a clinical study: intraday precision and accuracy of the CSF assay for calibration standards (0.025–10 μg/ml) and quality control samples (0.1, 0.5, and 2.5 μg/ml) were <6.2% coefficient of variation and 96.8–104.0% of nominal concentration, respectively.
机译:建立了在线萃取的灵敏反相高效液相色谱(RP-HPLC)分析法,用于定量人脑脊髓液(CSF)中的厄他培南。该测定方法的灵敏度至少是先前公布的厄他培南方法的五倍,定量下限为0.025 g / ml。在该测定中,使用RP萃取柱和含水酸性流动相(0.1%甲酸)在线萃取CSF样品,以洗去极性内源性物质,而厄他培南保留在柱上。然后将厄他培南反冲出萃取柱,并使用带有有机改性剂(乙腈/0.1%甲酸,15:85(v / v))的酸性流动相引导至RP分析柱,并使用UV吸光度进行检测。酸性流动相提供了更尖锐的色谱峰,并且在线提取允许在不损害色谱柱完整性的情况下进样大体积进样量(≥150μl)的缓冲脑脊液。这些测定条件对于定量以人类CSF(<0.05μg/ ml)中发现的厄他培南是必要的。该方法已成功验证并用于临床研究:校准标准液(0.025–10μg/ ml)和质量控制样品(0.1、0.5和2.5μg/ ml)的CSF分析的日内精密度和准确度<6.2%变异系数和标称浓度的96.8–104.0%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号