首页> 外文期刊>Journal of cataract and refractive surgery >Optimizing measurement of subjective amplitude of accommodation with defocus curves.
【24h】

Optimizing measurement of subjective amplitude of accommodation with defocus curves.

机译:使用散焦曲线优化对主观调节幅度的测量。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

PURPOSE: To determine whether letter sequences and/or lens-presentation order should be randomized when measuring defocus curves and to assess the most appropriate criterion for calculating the subjective amplitude of accommodation (AoA) from defocus curves. SETTING: Eye Clinic, School of Life & Health Sciences, Aston University, Birmingham, United Kingdom. METHODS: Defocus curves (from +3.00 diopters [D] to -3.00 D in 0.50 D steps) for 6 possible combinations of randomized or nonrandomized letter sequences and/or lens-presentation order were measured in a random order in 20 presbyopic subjects. Subjective AoA was calculated from the defocus curves by curve fitting using various published criteria, and each was correlated to subjective push-up AoA. Objective AoA was measured for comparison of blur tolerance and pupil size. RESULTS: Randomization of lens-presentation order and/or letter sequences, or lack of, did not affect the measured defocus curves (P >.05, analysis of variance). The range of defocusthat maintains highest achievable visual acuity (allowing for variability of repeated measurement) was better correlated to (r = 0.84) and agreed best with (+/-0.50 D) subjective push-up AoA than any other relative or absolute acuity criterion used in previous studies. CONCLUSIONS: Nonrandomized letters and lens presentation on their own did not affect subjective AoA measured by defocus curves, although their combination should be avoided. Quantification of subjective AoA from defocus curves should be standardized to the range of defocus that maintains the best achievable visual acuity.
机译:目的:确定在测量散焦曲线时是否应将字母序列和/或镜头的显示顺序随机化,并评估从散焦曲线计算适应性主观振幅(AoA)的最适当标准。地点:英国伯明翰阿斯顿大学生命与健康科学学院眼科。方法:在20位老花眼受试者中,以随机顺序测量了6种可能的随机或非随机字母序列和/或镜片呈现顺序组合的散焦曲线(从+3.00屈光度[D]到-3.00 D,以0.50 D的步长)。使用各种公开的标准通过曲线拟合从散焦曲线计算主观AoA,并将每个主观AoA与主观上推AoA相关联。测量了客观AoA,以比较模糊容忍度和瞳孔大小。结果:镜头呈现顺序和/或字母序列的随机化,或缺乏,均不影响测得的散焦曲线(P> .05,方差分析)。与其他相对或绝对敏锐度标准相比,保持最高可达到的敏锐度(允许重复测量的可变性)的散焦范围与(r = 0.84)更好地相关,并且与(+/- 0.50 D)主观上推AoA最佳吻合在以前的研究中使用。结论:尽管应避免将它们结合使用,但非随机字母和镜片的呈现本身不会影响通过散焦曲线测得的主观AoA。从散焦曲线对主观AoA的量化应标准化至散焦范围,以保持最佳可达到的视敏度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号