Impact of axis misalignment of toric intraocular lenses on refractive outcomes after cataract surgery.

机译:白内障手术后复曲面人工晶状体轴未对准对屈光结果的影响。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

PURPOSE: To theoretically and clinically evaluate the impact of axis misalignment of toric intraocular lenses (IOLs) on postoperative refraction. SETTING: International Vision Correction Research Center, University of Heidelberg, Heidelberg, Germany. DESIGN: Case series. METHODS: A method based on mathematical solutions to obliquely crossed spherocylinders was derived according to the pseudophakic refractive properties and used to analyze the impact of toric IOL misalignment on postoperative refraction. The refractive outcomes were theoretically analyzed and actual postoperative outcomes assessed to confirm the theoretically identified impact. RESULTS: The mean IOL misalignment was 12.5 degrees +/- 6.7 (SD). Three main factors had an impact on refractive outcomes: hyperopic change in refractive sphere, reduction in astigmatic correction, and rotation of the astigmatic axis. The mean calculated spherical change was 0.32 +/- 0.23 diopters (D) and the actual change, 0.36 +/- 0.71 D. The mean calculated reduction in astigmatic correction was 0.65 +/- 0.45 D and the actual reduction, 0.95 +/- 0.54 D, indicating undercorrection of preexisting astigmatism. The mean calculated absolute astigmatic rotation was 32.7 +/- 13.2 degrees (range 8 to 55 degrees) and the actual rotation, 29.1 +/- 17.4 degrees. There was a correlation between the calculated and actual reduction (r(2) = 0.51; P = .001) and between the calculated and actual rotation (r(2) = 0.86; P<.001). CONCLUSION: In addition to a reduction in astigmatic correction, misalignment of toric IOLs induced hyperopic spherical change and astigmatic rotation.
机译:目的:从理论和临床上评估复曲面人工晶状体(IOL)轴未对准对术后屈光的影响。地点:德国海德堡大学海德堡国际视力矫正研究中心。设计:案例系列。方法:根据伪晶状体屈光特性,提出了一种基于数学解的斜交球面圆柱体的方法,该方法用于分析复曲面IOL错位对术后屈光的影响。从理论上分析屈光结果并评估实际的术后结果,以确认理论上确定的影响。结果:平均IOL错位是12.5度+/- 6.7(SD)。影响屈光结果的三个主要因素是:屈光球的远视变化,散光矫正的减少以及散光轴的旋转。计算出的平均球面变化为0.32 +/- 0.23屈光度(D),实际变化为0.36 +/- 0.71D。平均计算出的散光矫正减少量为0.65 +/- 0.45 D,实际减少量为0.95 +/- 0.54 D,表示先前散光的矫正不足。平均计算的绝对像散旋转为32.7 +/- 13.2度(范围为8到55度),实际旋转为29.1 +/- 17.4度。计算出的和实际的减少量之间存在相关性(r(2)= 0.51; P = .001),计算出的和实际旋转量之间存在相关性(r(2)= 0.86; P <.001)。结论:除了减少散光矫正外,复曲面IOL的未对准还会引起远视球面改变和散光旋转。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号