首页> 外文期刊>Journal of cataract and refractive surgery >Changes in corneal wavefront aberrations in microincision and small-incision cataract surgery.
【24h】

Changes in corneal wavefront aberrations in microincision and small-incision cataract surgery.

机译:微切口和小切口白内障手术中角膜波前像差的变化。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

PURPOSE: To study the effect of incision size on the optical quality of the anterior cornea by comparing the changes in corneal wavefront aberrations between microincision cataract surgery (MICS) and small-incision cataract surgery (SICS). SETTING: Eye Hospital of Wenzhou Medical College, Wenzhou, Zhejiang, China. METHODS: This prospective randomized clinical study included 36 eyes having MICS (1.5 mm) and 38 eyes having SICS (3.0 mm). Anterior corneal topography was measured preoperatively and 3 to 6 months postoperatively. The data were used to calculate anterior corneal Zernike aberrations (through the 6th order) for a 6.0 mm central area. RESULTS: In the MICS group, 2 corneal Zernike aberrations (trefoil and tetrafoil) changed significantly from preoperatively to postoperatively (both P<.0001). In the SICS group, in addition to trefoil and tetrafoil, oblique astigmatism (P<.0001), secondary oblique astigmatism (P = .001), and vertical tetrafoil (P = .001) changed significantly. The SICS group had greater changes than the MICS group in oblique astigmatism (P = .0001), oblique trefoil (P = .0035), and vertical tetrafoil (P = .0023). The changes in the SICS group were significantly greater than in the MICS group in the total root mean square (RMS) (P = .007) and higher-order RMS (P = .023) of corneal wavefront aberrations. CONCLUSIONS: Cataract surgery-related changes in corneal wavefront aberrations were dependent on incision size. The MICS technique had advantages over the SICS technique in minimizing the effect of the incision size on the optical quality of the cornea.
机译:目的:通过比较微切口白内障手术(MICS)和小切口白内障手术(SICS)的角膜波前像差的变化,研究切口大小对前角膜光学质量的影响。单位:温州医学院眼科医院,浙江温州。方法:这项前瞻性随机临床研究包括36眼具有MICS(1.5毫米)的眼和38眼具有SICS(3.0毫米)的眼。术前和术后3至6个月测量前角膜地形图。数据用于计算中心区域6.0 mm的角膜前Zernike像差(通过6阶)。结果:在MICS组中,两个角膜Zernike像差(三叶形和四叶形)从术前到术后均发生了显着变化(均P <.0001)。在SICS组中,除了三叶形和四叶形之外,斜散光(P <.0001),继发性斜散光(P = .001)和垂直四叶形(P = .001)也发生了显着变化。 SICS组在斜散光(P = .0001),斜三叶形(P = .0035)和垂直四翼(P = .0023)方面比MICS组具有更大的变化。在角膜波前像差的总均方根(RMS)(P = .007)和高阶RMS(P = .023)方面,SICS组的变化明显大于MICS组。结论:白内障手术相关的角膜波前像差变化取决于切口大小。在最小化切口尺寸对角膜光学质量的影响方面,MICS技术优于SICS技术。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号