首页> 外文期刊>Journal of cataract and refractive surgery >Retinal straylight in patients with monofocal and multifocal intraocular lenses.
【24h】

Retinal straylight in patients with monofocal and multifocal intraocular lenses.

机译:单焦点和多焦点人工晶状体患者的视网膜杂散光。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

PURPOSE: To determine the differences in retinal straylight perceived by patients with monofocal intraocular lenses (IOLs) and patients with multifocal IOLs. SETTING: Vissum-Instituto de Oftalmologico de Alicante, Alicante, Spain. METHODS: In this prospective study, contrast sensitivity and retinal straylight were measured prospectively 6 months postoperatively in 67 eyes of 40 patients with a monofocal or multifocal IOL. In the monofocal group, a ThinOptX IOL (ThinOptX, Inc.) was implanted in 12 eyes and an Acri.Smart 48 S IOL (Acri.Tec) in 20 eyes. In the multifocal IOL group, a ReZoom IOL (Advanced Medical Optics) was implanted in 13 eyes and a ReSTOR IOL (Alcon Laboratories) in 22 eyes. RESULTS: All measured values were similar between the monofocal and multifocal groups. Contrast sensitivity correlated significantly with the retinal straylight value (r= 0.258; P= .026) and the mean residual spherical equivalent. There was no statistically significant relationship between IOL type and the retinal straylight value (P= .089). Adjusted mean scores suggest that straylight values in the monofocal group were slightly higher than in the multifocal group. In the monofocal group, retinal straylight values were significantly correlated with pupil size (r= -0.377; P= .033). In the multifocal group, a correlation was found between retinal straylight values and contrast sensitivity (r= 0.397; P= .024). After controlling for age differences, there were no significant differences in retinal straylight between IOLs (P= .069). CONCLUSIONS: No significant differences in straylight values were found between multifocal IOLs and monofocal IOLs. Pupil miosis during retinal straylight measurement and neural adaptation after multifocal IOL implantation may overcome differences between IOLs.
机译:目的:确定单焦点人工晶状体(IOL)患者和多焦点人工晶状体患者的视网膜杂散光的差异。地点:西班牙阿利坎特,阿利坎特市立圣母学院。方法:在这项前瞻性研究中,对40例单焦点或多焦点IOL患者的67眼术后6个月进行了对比敏感性和视网膜杂散光测量。在单焦点组中,将ThinOptX IOL(ThinOptX,Inc.)植入12眼,将Acri.Smart 48 S IOL(Acri.Tec)植入20眼。在多焦点IOL组中,ReZoom IOL(高级医疗光学)被植入13眼,而ReSTOR IOL(Alcon Laboratories)被植入22眼。结果:单焦点和多焦点组的所有测量值均相似。对比度灵敏度与视网膜杂散光值(r = 0.258; P = .026)和平均残余球当量显着相关。 IOL类型与视网膜杂散光值之间无统计学意义的相关性(P = .089)。调整后的平均得分表明,单焦点组的杂散光值略高于多焦点组。在单焦点组中,视网膜杂散光值与瞳孔大小显着相关(r = -0.377; P = .033)。在多焦点组中,发现视网膜杂散光值与对比敏感度之间存在相关性(r = 0.397; P = .024)。在控制了年龄差异之后,IOL之间的视网膜杂散光没有显着差异(P = .069)。结论:多焦点IOL和单焦点IOL在杂散光值上没有发现显着差异。视网膜杂散光测量期间的瞳孔缩小和多焦点人工晶状体植入后的神经适应可以克服人工晶状体之间的差异。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号